开发 Dev #111194

开发 Dev #110122: 【MK】管理总票

开发 Dev #110125: 【MK】【BSP】管理总票

开发 Dev #111193: 【MK】【028】【PWM】主任务

【MK】【028】【PWM】【TC-RID: 1201-0102801】PWM 驱动bring up

Added by CD TPM-申艳艳 almost 3 years ago. Updated over 2 years ago.

Status:完成 ClosedStart date:2022-08-11
Priority:NormalDue date:2022-08-11
Assignee:SZTS_TEST 邹涛% Done:

100%

Category:BSP
Target version:VX1_MCE_FSE_V2.0_20220930

Description

请填写信息:
■需求列表:
https://thundersoft.feishu.cn/sheets/shtcnqaFyklNSnMcKWLulCI3xnc
■提出URL:必填
■自测case:必填
■注意点:需要测试注意的前提条件

History

#1 Updated by SZ TPM-罗云进 almost 3 years ago

  • Due date set to 2022-08-11
  • Assignee changed from SZ TPM-罗云进 to SZTS_TEST 邹涛
  • Target version set to 588
  • % Done changed from 0 to 90

■提出URL:https://dev.thundercomm.com/gerrit/#/c/142173/
■自测case:
1.烧录08/11之后的版本
2.烧录完开机之后,风扇会按照默认的占空比60%转

#2 Updated by SZTS_TEST 邹涛 almost 3 years ago

  • Assignee changed from SZTS_TEST 邹涛 to SZ TPM-罗云进

N代表占空比,0-100,数值越大,风扇转速越高
echo N>/sys/devices/platform/vendor/vendor:qcom,fan_f/pwm_duty

软件版本: 0.0.0.20220816_alpha_private
使用如上命令可以控制风扇转速,开机查看风扇转速,研发未提供

#3 Updated by SZ TPM-罗云进 almost 3 years ago

  • Status changed from New to 解决 Resolved
  • Assignee changed from SZ TPM-罗云进 to SZTS_TEST 邹涛
  • % Done changed from 90 to 100

#4 Updated by CD SWPM-杨宏伟 almost 3 years ago

  • Target version changed from 588 to VX1_MCE_FSE_V2.0_20220930

#5 Updated by SZTS_TEST 邹涛 almost 3 years ago

  • Status changed from 解决 Resolved to 完成 Closed

0924release版本验证
风扇在开机时会自动转动一次,之后根随主板温度转动、测试过程中升温可以使用电吹风进行加热,并使用命令实时查看温度值
当前的风扇分为三档:一档转速比值102、二档153、三档204
温度对应的风扇动作:
1、0~49.9 风扇不动
2、50~60,风扇一档
3、60~75.风扇为二档
4、75以上、风扇为三档"

#6 Updated by CD FW-王伟 over 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
142173 general/LINUX/android/vendor/qcom/proprietary Pre_figure_turbox-c2130c-la1.1-vendor-dev
BSP:PWM:Bringup PWM fan(1/2)
Add the Fan device node and relative PWM in DT
TC-RID: 1201-0102801
IssueID: TC-R-DF-111194
Change-Id: I15a197ac4908c26ca5262fda44a1469058238dc6

#7 Updated by CD FW-王伟 over 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
142177 general/kernel/msm-4.19 Pre_figure_turbox-c2130c-la1.1-vendor-dev
BSP:PWM:Bringup PWM fan(2/2)
Add relative driver for PWM fan, and you can adjuest fan rate by
command: "echo xxx >/sys/devices/platform/vendor/vendor:qcom,fan_f/pwm_duty"
TC-RID: 1201-0102802
IssueID: TC-R-DF-111194
Change-Id: I713da9c52c247465df9d4a5a90d4b8c7a95b8d84