Bug #111735
【Figure】【EVT】【电气性能】E07 电压缓降快升:试验中,电压下降到 9.6V 时,WiFi,蓝牙,视频和以太网功能失效,试验后,重新上 电操作,WiFi,蓝牙,视频和以太网功能正常。
Status: | CLOSED | Start date: | 2022-09-05 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | SZ HW Test-曾小文 | % Done: | 0% | |
Category: | CD-FW | |||
Target version: | VX1_MCE_FSE_V2.0_20220930 | |||
Need_Info: | -- | Found Version: | 2022.08.25 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
History
#1 Updated by CD TPM-申艳艳 almost 3 years ago
- Category set to EE
#2 Updated by SZ HW Test-曾小文 almost 3 years ago
- Subject changed from 【Figure】【EVT】【电气性能】E07 电压缓降快升:过程中样机中断工作,低压不能工作,无法自己恢复 to 【Figure】【EVT】【电气性能】E07 电压缓降快升:试验中,电压下降到 9.6V 时,WiFi,蓝牙,视频和以太网功能失效,试验后,重新上 电操作,WiFi,蓝牙,视频和以太网功能正常。
#3 Updated by IOT-SP-TEST 刘颖 almost 3 years ago
- Assignee changed from SZ-硬件二组_SD3 王苗 to CD TPM-申艳艳
Class C需要记忆,软件OS需要做记忆
#4 Updated by CD TPM-申艳艳 almost 3 years ago
- Category changed from EE to CD-FW
- Assignee changed from CD TPM-申艳艳 to CD- FW-石豪
Hi 石豪,
这个问题用来跟踪和 MCU 连携问题,歇息
#5 Updated by CD FW-王伟 almost 3 years ago
- Target version set to VX1_MCE_FSE_V2.0_20220930
#6 Updated by CDTS_TEST 王成 almost 3 years ago
9.27号入代码--石豪
#7 Updated by CD TPM-申艳艳 almost 3 years ago
- Assignee changed from CD- FW-石豪 to SZ HW Test-曾小文
Hi 小文,
代码已经入库, 请验证。
#8 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from New to ASSIGNED
#9 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from ASSIGNED to RESOLVED
#10 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#11 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED
更新MCU软件,增加记忆功能,复测PASS