Bug #111887
【Figure】【EVT】【电气性能】E14 短路保护:GMSL信号脚对地短路不能恢复,需重启恢复,16V时GMSL对Ub短路有时会掉端口和黑屏需重启恢复。 无短路保护功能。
Status: | CLOSED | Start date: | 2022-09-09 | |
---|---|---|---|---|
Priority: | High | Due date: | 2022-09-28 | |
Assignee: | SZ HW Test-曾小文 | % Done: | 0% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 2022.09.04 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
E14 短路保护:GMSL信号脚对地短路不能恢复,需重启恢复,16V时GMSL对Ub短路有时会掉端口和黑屏需重启恢复。
无短路保护功能。
History
#1 Updated by CD BSP-唐金泽 almost 3 years ago
- Category set to BSP
- Status changed from New to ASSIGNED
- Assignee changed from CD BSP-唐金泽 to CD BSP-余霄
#2 Updated by IOT-SP-TEST 刘颖 almost 3 years ago
- Due date set to 2022-09-28
- Assignee changed from CD BSP-余霄 to SZ-硬件二组_SD3 王苗
需要核对测试方法,金辉帮忙看下客户提供过来的文档,与硬测的方法是否一致;
#3 Updated by CD BSP-余霄 almost 3 years ago
请帮忙提供一下测试方法,目前我验证时对地短接后,设备自动重启,无法复现现象。
#4 Updated by SZ-硬件二组_SD3 王苗 almost 3 years ago
- Assignee changed from SZ-硬件二组_SD3 王苗 to CD BSP-余霄
更硬测确认,只有在CMSL那个连接器的4个PIN分别对GND短路的时候会出现问题。可以用镊子单独对GMSL的4个PIN的每个pin在开机正常显示过程中测试每个PIN对GND短路后的结果。
#5 Updated by CD BSP-余霄 over 2 years ago
同如下问题,短路后也重新执行reset并执行初始化流程,目前正在FIX:
https://share.thundersoft.com/redmine/issues/111886
#6 Updated by CD BSP-余霄 over 2 years ago
- Assignee changed from CD BSP-余霄 to CDTS_TEST 王成
同如下问题 需要修改时间 请确认
https://share.thundersoft.com/redmine/issues/111886
#8 Updated by CD BSP-余霄 over 2 years ago
- Status changed from ASSIGNED to RESOLVED
#9 Updated by CD BSP-余霄 over 2 years ago
- Assignee changed from CD BSP-余霄 to CDTS_TEST 王成
#10 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
- Assignee changed from CDTS_TEST 王成 to SZ HW Test-曾小文
userdebug.0.0.0.20221018版本复测PASS。
#11 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED