Bug #113426
【Figure】【EVT2】【RF】无高通端口,无法测试
Status: | CLOSED | Start date: | 2022-11-01 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | SZ HW Test-曾小文 | % Done: | 100% | |
Category: | BSP | |||
Target version: | 依赖硬件的bugList | |||
Need_Info: | -- | Found Version: | FlatBuild_HH_VX1_MCE_FSE.M.R.userdebug.01.00.0040.X101 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
有安卓投屏端口,但是无高通端口,无法测试,RF硬件31号修改了新参数,未合入版本
History
#1 Updated by CD BSP-唐金泽 over 2 years ago
- Target version set to 依赖硬件的bugList
#2 Updated by CD BSP-唐金泽 over 2 years ago
- Status changed from New to NEED_INFO
- Assignee changed from CD BSP-唐金泽 to SZ HW Test-曾小文
- % Done changed from 0 to 100
已验证过adb 和高通901d端口。
请帮忙明确无法读取高通端口哪个端口的具体期待
#3 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from NEED_INFO to RESOLVED
#4 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
FlatBuild_HH_VX1_MCE_FSE.M.R.userdebug.01.00.0042.X101 版本已解决该问题
#5 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED