Bug #113713
【Figure】【EVT2】【百兆以太网_IOP】LINK UP/SQI/诊断测试Fail
Status: | CLOSED | Start date: | 2022-11-04 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | 依赖软件规避的bug | |||
Target version: | MCE_V4.0update_20221215(原VC1_FSE_Vdec1219) | |||
Need_Info: | -- | Found Version: | FlatBuild_HH_VX1_MCE_FSE.M.R.userdebug.01.00.0042.X101 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
测试结果请参考附件
History
#1 Updated by IOT-SP-TEST 刘颖 over 2 years ago
- Target version set to 依赖硬件的bugList
#2 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from SZ-硬件二组_SD3 王苗 to IOT-SP-TEST 刘颖
已经提供1000M与100M测试报告,请软件先检查下100M寄存器配置。
#3 Updated by IOT-SP-TEST 刘颖 over 2 years ago
- Assignee changed from IOT-SP-TEST 刘颖 to CD_BSP 彭文亮
#4 Updated by IOT-SP-TEST 刘颖 over 2 years ago
- Category changed from EE to 依赖软件规避的bug
#5 Updated by CD_BSP 彭文亮 over 2 years ago
- % Done changed from 0 to 60
LINK UP/SQI/VCT测试,经过近2周的研究、分析、测试和讨论。 均已经进行进行了针对性修复。编译包。等待实验室进行结果的验证。
#6 Updated by CD BSP-唐金泽 over 2 years ago
- Target version changed from 依赖硬件的bugList to MCE_V4.0update_20221215(原VC1_FSE_Vdec1219)
测试机构已验证,通过,@文亮,请考虑如何合入dev分支版本。
#8 Updated by IoT scm over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
167212 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP: MCU:Added MCU notification MPU networking function Used to pass the network connection test, it is necessary to strictly control the network connection time and add a timing function on the MCU side. Bin version: V0.0.6 TC-RID: 1201-0102704 IssueID: TS-R-DF-113713 Change-Id: Ib66489af16bb81609f2405b660687b37336809fe |
#9 Updated by IoT scm over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
167377 | general/platform/vendor/thundercomm/uart | Pre_figure_turbox-c2130c-la1.1-vendor-dev | tangjz1204@thundersoft.com |
BSP:UART: Enable PHY linkup When get MCU Message enable phy linkup when get mcu message TC-RID: 1201-0400603 IssueID: TS-R-DF-113713 Change-Id: Iff0a9db910a95acc9fde745c25d0bda7fa540554 |
#10 Updated by IoT scm over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
167850 | general/platform/vendor/thundercomm/uart | Pre_figure_turbox-c2130c-la1.1-vendor-dev | tangjz1204@thundersoft.com |
BSP:UART: Exchange Uart Service priority exchange uart service priority TC-RID: 1201-0400603 IssueID: TS-R-DF-113713 Change-Id: I9476ef67ce0267ccf453e5a259bc76676bbddabb |
#11 Updated by IoT scm over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
166247 | general/kernel/msm-4.19 | Pre_figure_turbox-c2130c-la1.1-vendor-dev | wenliang.peng@thundersoft.com |
BSP:Ethernet: for 100M IOP test Initial: Items(linkup02, linkup03, sqi02)test fail. After modification: All items can pass the test. We recommend using the perf version for IOP testing. TC-RID: 0301-0400601 IssueID: TS-R-DF-113713 Change-Id: Ie28af1e44e36b66cb28d3def0119be68c1e9ab05 |
#12 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD_BSP 彭文亮 to CDTS_TEST 王成
- % Done changed from 70 to 100
#13 Updated by CDTS_TEST 王成 over 2 years ago
- Assignee changed from CDTS_TEST 王成 to 移动测试一组_CDTS 刘强
#14 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from RESOLVED to VERIFIED
由于硬件IOP测试已经通过
软件检测连接以太网盒子后可以正常上网浏览网页
且DTC Ethernet盒子网络移除时会诊断报以下日志:
01-01 08:05:28.227 0 0 E DTC_ETH,link_delay_work_func: 3003, SQI=0, link=0
恢复链接后,报错日志消失
验证版本:FlatBuild_HH_VX1_MCE_FSE.M.D.userdebug.01.00.X101.202301191306
#15 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from VERIFIED to CLOSED