【Figure】【EVT2】【腐蚀】盐雾测试:有3个样品测试后产品不工作(其中1个带亚克力盒子),6个样品外观都有腐蚀

Added by SZ HW Test-曾小文 over 2 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2022-12-14
Priority:HighDue date:
Assignee:SZ HW Test-曾小文% Done:

100%

Category:其他硬件bug
Target version:-
Need_Info:-- Found Version:FlatBuild_VX1_MCE_xx.xx_FSE.D.userdebug.0.0.0.20221024.alpha.zip
Resolution:FIXED Degrated:No
Severity:Normal Verified Version:
Reproducibility:Frequently Fixed Version:2023-02-25
Test Type:Release Test Root cause:盐雾直接进入主板导致主板短路

Description

盐雾测试(共测试6台):
有3个样品测试后产品不工作(其中1个带亚克力盒子),6个样品外观都有腐蚀

History

#1 Updated by SZ HW Test-曾小文 over 2 years ago

  • Category set to 其他硬件bug

#2 Updated by SZ HW Test-曾小文 over 2 years ago

  • Assignee changed from SZ-硬件二组_SD3 王苗 to 物联网项目组-RD3_CDTS 周飞

#3 Updated by 物联网项目组-RD3_CDTS 周飞 over 2 years ago

  • Assignee changed from 物联网项目组-RD3_CDTS 周飞 to 交付部_BM 陈勇

#4 Updated by 交付部_BM 陈勇 over 2 years ago

  • Status changed from New to RESOLVED
  • % Done changed from 0 to 100
  • Resolution changed from -- to FIXED
  • Degrated changed from -- to No
  • Fixed Version set to 2023-02-25
  • Root cause set to 盐雾直接进入主板导致主板短路

#5 Updated by CD- QA-廖明霞 over 2 years ago

  • Assignee changed from 交付部_BM 陈勇 to SZ HW Test-曾小文

#6 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

#7 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from VERIFIED to CLOSED

后续增加三防漆,客户认可放置一段时间后测试,测试结果PASS