Bug #114547
【Figure】【EVT2】【腐蚀】盐雾测试:有3个样品测试后产品不工作(其中1个带亚克力盒子),6个样品外观都有腐蚀
Status: | CLOSED | Start date: | 2022-12-14 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | SZ HW Test-曾小文 | % Done: | 100% | |
Category: | 其他硬件bug | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | FlatBuild_VX1_MCE_xx.xx_FSE.D.userdebug.0.0.0.20221024.alpha.zip | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Frequently | Fixed Version: | 2023-02-25 | |
Test Type: | Release Test | Root cause: | 盐雾直接进入主板导致主板短路 |
Description
盐雾测试(共测试6台):
有3个样品测试后产品不工作(其中1个带亚克力盒子),6个样品外观都有腐蚀
History
#1 Updated by SZ HW Test-曾小文 over 2 years ago
- Category set to 其他硬件bug
#2 Updated by SZ HW Test-曾小文 over 2 years ago
- Assignee changed from SZ-硬件二组_SD3 王苗 to 物联网项目组-RD3_CDTS 周飞
#3 Updated by 物联网项目组-RD3_CDTS 周飞 over 2 years ago
- Assignee changed from 物联网项目组-RD3_CDTS 周飞 to 交付部_BM 陈勇
#4 Updated by 交付部_BM 陈勇 over 2 years ago
- Status changed from New to RESOLVED
- % Done changed from 0 to 100
- Resolution changed from -- to FIXED
- Degrated changed from -- to No
- Fixed Version set to 2023-02-25
- Root cause set to 盐雾直接进入主板导致主板短路
#5 Updated by CD- QA-廖明霞 over 2 years ago
- Assignee changed from 交付部_BM 陈勇 to SZ HW Test-曾小文
#6 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#7 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED
后续增加三防漆,客户认可放置一段时间后测试,测试结果PASS