Bug #117567
【PVC1-1143】【FSE-M】【以太网】【刷写】刷写 测试问题
Status: | CLOSED | Start date: | 2023-04-19 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | 物联网测试组_TSCD 王维 | % Done: | 100% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 01.00.0094.C103版本 | |
Resolution: | FIXED | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | ST | Root cause: | #117329已解决 |
Description
使用0x1C2002作为一个块刷写,3601必现无响应
使用0xFEB02作为一个块刷写,几率性在某一个块刷写失败
【备注】
安卓原生系统与以太网诊断服务偶发同时对以太网控制模式寄存器0x8034进行异步刷写,导致出现异常,从而引起传输功能异常;
对控制模式寄存器0x8034修改值为正常值后,电路板基本能回复正常。将优化以太网诊断方案。
01.00.0094.C103版本回归 (4/25)
History
#1 Updated by CD BSP 叶鹏 about 2 years ago
- Assignee changed from CD BSP 叶鹏 to CD_BSP 彭文亮
#2 Updated by CD_BSP 彭文亮 about 2 years ago
此BUG与 https://share.thundersoft.com/redmine/issues/117329#change-542815 重复, 均是来源于客户jira 583。 该如何关闭此BUG?
#3 Updated by CD BSP-杜磊 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD_BSP 彭文亮 to 物联网测试组_TSCD 王维
- % Done changed from 0 to 100
#4 Updated by CD BSP-杜磊 about 2 years ago
- Resolution changed from -- to FIXED
- Root cause set to #117329已解决
#5 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#6 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from VERIFIED to CLOSED