开发 Dev #110662

开发 Dev #110122: 【MK】管理总票

开发 Dev #110125: 【MK】【BSP】管理总票

开发 Dev #110660: 【MK】【027】【MCU】主任务

【MK】【027】【MCU】【TC-RID: 1201-0102702】Can指令收发与解析

Added by CD TPM-申艳艳 almost 3 years ago. Updated about 2 years ago.

Status:进行中 In ProgressStart date:2022-10-27
Priority:NormalDue date:
Assignee:CD BSP-陈杰% Done:

90%

Category:BSP
Target version:-

Description

请填写信息:
■需求列表:
https://thundersoft.feishu.cn/sheets/shtcnqaFyklNSnMcKWLulCI3xnc L51
Can指令收发与解析
■提出URL:必填
■自测case:必填
■注意点:需要测试注意的前提条件


Subtasks

开发 Dev #113240: 【MK】【027】【MCU】【TC-RID: 1201-0102702】can通知MPU关机进行中 In ProgressCD BSP-陈杰

开发 Dev #113241: 【MK】【027】【MCU】【TC-RID: 1201-0102702】Can指令解析,设备重启进行中 In ProgressCD BSP-陈杰

开发 Dev #113243: 【MK】【027】【MCU】【TC-RID: 1201-0102702】Can通知MCU走上电流程未着手 Not StartedCD BSP-陈杰

History

#1 Updated by SZ TPM-罗云进 almost 3 years ago

  • Category changed from 714 to 709
  • Assignee changed from SZ TPM-罗云进 to SZ BSP-徐季源

#2 Updated by CD TPM-申艳艳 almost 3 years ago

  • Subject changed from 【MK】【029】【MCU】【TC-RID: 0301-0102902】Can指令收发与解析 to 【MK】【029】【MCU】【TC-RID: 1201-0102702】Can指令收发与解析

#3 Updated by CD TPM-申艳艳 almost 3 years ago

  • Subject changed from 【MK】【029】【MCU】【TC-RID: 1201-0102702】Can指令收发与解析 to 【MK】【027】【MCU】【TC-RID: 1201-0102702】Can指令收发与解析

#4 Updated by SZ BSP-徐季源 almost 3 years ago

  • Status changed from New to 进行中 In Progress
  • % Done changed from 0 to 50

CAN 通路已通,等待协议拟定

#5 Updated by SZ BSP-徐季源 almost 3 years ago

  • Assignee changed from SZ BSP-徐季源 to CD BSP-陈杰

#6 Updated by CD BSP-唐金泽 over 2 years ago

  • Category set to BSP

依赖CAN协议,请PM确定CAN协议集成计划

#7 Updated by CD BSP-唐金泽 over 2 years ago

已由PM明确,通过CAN 驱动解析,开机、关机、重启该三条命令,并做动作执行

#8 Updated by IoT scm about 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
191534 Pre_figure/mcu Pre_figure_turbox-c2130c-la1.1-vendor-dev
BSP:MCU: Fix the watchdog problem
After a new mot file is flushed in for repair, upgrading a
new bin file can cause the device to continuously restart.
The reason for restarting is that the feed dog in the boot
does not take effect, and the watchdog in the app code is running, resulting in continuous restarts.
TC-RID: 1201-0102704
IssueID: TS-R-DF-110662
Change-Id: Ic3e1a21bb23680e08d620ca0b3658b471e7ba94d

Also available in: Atom PDF