开发 Dev #111195
开发 Dev #110122: 【MK】管理总票
开发 Dev #110125: 【MK】【BSP】管理总票
开发 Dev #111193: 【MK】【028】【PWM】主任务
【MK】【028】【PWM】【TC-RID: 1201-0102802】echo指令控制pwm占空比控制风扇转速
Status: | 完成 Closed | Start date: | 2022-08-11 | |
---|---|---|---|---|
Priority: | Normal | Due date: | 2022-08-11 | |
Assignee: | SZ TPM-罗云进 | % Done: | 100% | |
Category: | BSP | |||
Target version: | VX1_MCE_FSE_V2.0_20220930 |
Description
请填写信息:
■需求列表:
https://thundersoft.feishu.cn/sheets/shtcnqaFyklNSnMcKWLulCI3xnc
■提出URL:必填
■自测case:必填
■注意点:需要测试注意的前提条件
History
#1 Updated by SZ TPM-罗云进 almost 3 years ago
- Due date set to 2022-08-11
- Assignee changed from SZ TPM-罗云进 to SZTS_TEST 邹涛
- Target version set to 588
- % Done changed from 0 to 90
■提出URL:https://dev.thundercomm.com/gerrit/#/c/142177/
■自测case:
Add relative driver for PWM fan, and you can adjuest fan rate by
command: "echo xxx >/sys/devices/platform/vendor/vendor:qcom,fan_f/pwm_duty"
#2 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Assignee changed from SZTS_TEST 邹涛 to SZ TPM-罗云进
N代表占空比,0-100,数值越大,风扇转速越高
echo N>/sys/devices/platform/vendor/vendor:qcom,fan_f/pwm_duty
软件版本:0.0.0.20220816_alpha_private
使用如上命令验证,可以正常控制风扇转速
#3 Updated by SZ TPM-罗云进 almost 3 years ago
- Status changed from New to 完成 Closed
- % Done changed from 90 to 100
#4 Updated by CD SWPM-杨宏伟 almost 3 years ago
- Target version changed from 588 to VX1_MCE_FSE_V2.0_20220930