Bug #111421
【Figure】【EVT2】【EE】过压保护:关机电压17V,恢复电压16.4V,标准16.5V
Status: | 完成 Closed | Start date: | 2022-08-23 | |
---|---|---|---|---|
Priority: | High | Due date: | 2022-11-03 | |
Assignee: | SZ HW Test-曾小文 | % Done: | 100% | |
Category: | 依赖软件规避的bug | |||
Target version: | VX1_MCE_FSE_V2.0_20220930 | |||
Need_Info: | Found Version: | 10.24版本 | ||
Resolution: | Degrated: | |||
Severity: | Critical | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
副驾设备要求9~16V的电压工作范围。
History
#1 Updated by SZ BSP-徐季源 almost 3 years ago
等待外派测试结果
#2 Updated by SZ BSP-徐季源 almost 3 years ago
- Tracker changed from Bug to 开发 Dev
- Status changed from New to 进行中 In Progress
ADC 过压保护属于新需求,而非 bug。目前已确定由深圳进行开发
#4 Updated by SZ BSP-徐季源 almost 3 years ago
- Assignee changed from SZ BSP-徐季源 to CD BSP-陈杰
#5 Updated by SZ HW Test-曾小文 almost 3 years ago
- Category set to EE
#6 Updated by IOT-SP-TEST 刘颖 almost 3 years ago
- Due date set to 2022-09-26
#7 Updated by CD BSP-陈杰 almost 3 years ago
- File FigureApp.mot added
- % Done changed from 80 to 100
目前已经交给硬测进行测试,并测试通过。上传了下载文件。
#8 Updated by CD BSP-陈杰 almost 3 years ago
- File FigureApp.mot added
- Status changed from 进行中 In Progress to 解决 Resolved
- Assignee changed from CD BSP-陈杰 to CD BSP-杜磊
- Target version set to VX1_MCE_FSE_V2.0_20220930
目前已完成功能开发,代码已经提交,给到硬测同事测试,功能测试正常。
https://dev.thundercomm.com/gerrit/c/Pre_figure/mcu/+/152609
#9 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from 解决 Resolved to 完成 Closed
#10 Updated by SZ HW Test-曾小文 over 2 years ago
- Tracker changed from 开发 Dev to Bug
- Subject changed from 【Figure】【EVT】【EE】3.5V就能开机,20V无过压保护 to 【Figure】【EVT】【EE】过压保护:关机电压17V,恢复电压16.4V,标准16.5V
- Category changed from EE to 依赖软件规避的bug
- Assignee changed from CD BSP-杜磊 to CD BSP-陈杰
- Severity set to Critical
- Reproducibility set to Every time
- Test Type set to Release Test
- Found Version set to FlatBuild_HH_VX1_MCE_FSE.M.R.userdebug.01.00.0040.X101
EVT2复测:过压保护:关机电压17V,恢复电压16.4V,标准16.5V
#11 Updated by SZ HW Test-曾小文 over 2 years ago
- Tracker changed from Bug to 需求 Requirement
- Status changed from 完成 Closed to 未着手 Not Started
#12 Updated by SZ HW Test-曾小文 over 2 years ago
- Tracker changed from 需求 Requirement to Bug
- Severity set to Critical
- Reproducibility set to Every time
- Test Type set to Release Test
- Found Version set to 2022.10.24版本
#13 Updated by CDTS-TEST 周婷 over 2 years ago
- Target version changed from VX1_MCE_FSE_V2.0_20220930 to VX1_MCE_FSE_V3.0_update_20221115
#14 Updated by CD BSP-陈杰 over 2 years ago
- Assignee changed from CD BSP-陈杰 to SZ HW Test-曾小文
- Target version changed from VX1_MCE_FSE_V3.0_update_20221115 to VX1_MCE_FSE_V2.0_20220930
- Resolution set to FIXED
- Found Version changed from 2022.10.24版本 to 版本使用20221102后的版本进行验证
- Degrated set to No
- Fixed Version set to 2022-11-02
目前代码已经入库,需要明天出版本后给到硬测进行测试。
#15 Updated by SZ HW Test-曾小文 over 2 years ago
- Subject changed from 【Figure】【EVT】【EE】过压保护:关机电压17V,恢复电压16.4V,标准16.5V to 【Figure】【EVT2】【EE】过压保护:关机电压17V,恢复电压16.4V,标准16.5V
- Assignee changed from SZ HW Test-曾小文 to CD BSP-陈杰
#16 Updated by CDTS-TEST 周婷 over 2 years ago
- Status changed from 未着手 Not Started to 进行中 In Progress
#17 Updated by IOT-SP-TEST 刘颖 over 2 years ago
- Due date changed from 2022-09-26 to 2022-11-03
#18 Updated by CD BSP-陈杰 over 2 years ago
问题已经解决,明天的版本进行测试
#19 Updated by CD BSP-陈杰 over 2 years ago
- Assignee changed from CD BSP-陈杰 to 项目二组_SD3 曾小文
- Found Version changed from 版本使用20221102后的版本进行验证 to 20221103日的DB版本
请使用今天我发给你的版本进行测试
#20 Updated by SZ HW Test-曾小文 over 2 years ago
- Assignee changed from 项目二组_SD3 曾小文 to CD BSP-陈杰
#21 Updated by CD BSP-陈杰 over 2 years ago
- Assignee changed from CD BSP-陈杰 to SZ HW Test-曾小文
- Found Version changed from 20221103日的DB版本 to 20221108日的DB版本
- Fixed Version changed from 2022-11-02 to 2022-11-08
可以使用今天的DB进行测试
#22 Updated by CD BSP-陈杰 over 2 years ago
更加实验室要求:
他的电压需要恢复至16V,测试过电压大于等于额17V;
所以进行了入夏设定:
高压:在16V-16.4V之间恢复都是正常,可通过,过压:在16.5V-17V保护为正常;
低压:在8.6V-9V之间恢复都是正常,可通过,过压:在8.5V-8V保护为正常.
麻烦进行测试一下
#23 Updated by SZ HW Test-曾小文 over 2 years ago
- Tracker changed from Bug to 测试 Test-IT
- Status changed from 进行中 In Progress to 完成 Closed
更新MCU后复测PASS
#24 Updated by SZ HW Test-曾小文 over 2 years ago
- Tracker changed from 测试 Test-IT to Bug
- Severity set to Critical
- Reproducibility set to Every time
- Test Type set to Release Test
- Found Version set to 10.24版本
请把复测版本贴上,你们点击一下resolved,再点成verified,再指给我,要不然我关不掉
#25 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
152609 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP:MCU: MCU code buring up, storage, and feature integration This commit protects the following functions: 1. Buring up of MCU code 2. Solve the power-on and power-on sequence bug 3. Increase the voltage protection function 4. MCU firmware upgrade function TC-RID: 1201-0102701 TC-RID: 1201-0102703 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111416 IssueID: TS-R-BUG-111734 IssueID: TS-R-BUG-111732 IssueID: TS-R-BUG-112002 IssueID: TS-R-DF-111421 IssueID: TS-R-DF-112099 IssueID: TS-R-DF-110660 IssueID: TS-R-DF-110663 IssueID: TS-R-DF-110664 Change-Id: Iacb3bbd40b9278405f21f5d34d741dfe08c3c4ff |
#26 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
152787 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP: MCU: Add firmware for MCU programming and upgrade The firmware version information is V0.0.1, which is the initial version. Implementation function: 1. Increase the power-on sequence 2. Increase the voltage protection function 3. Add version information TC-RID: 1201-0102701 TC-RID: 1201-0102703 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111416 IssueID: TS-R-BUG-111734 IssueID: TS-R-BUG-111732 IssueID: TS-R-BUG-112002 IssueID: TS-R-DF-111421 IssueID: TS-R-DF-112099 IssueID: TS-R-DF-110660 IssueID: TS-R-DF-110663 IssueID: TS-R-DF-110664 Change-Id: I047b1483f36d87a7a080b1470eb836cbc620a06e |
#27 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
154928 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP:MCU: Functional integration version of the MCU This version contains the following functions: 1.Improve the overvoltage protection function and increase the over-voltage protection communication with the MMU; 2.Improve the function of power-on and power-up sequence, and fix the problem that the boot screen is not displayed; 3.increase the can communication through, currently only open the can's transceiver, there is no integration of other can's functions. TC-RID: 1201-0102701 TC-RID: 1201-0102703 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111416 IssueID: TS-R-BUG-111734 IssueID: TS-R-BUG-111732 IssueID: TS-R-BUG-112002 IssueID: TS-R-DF-111421 IssueID: TS-R-DF-112099 IssueID: TS-R-DF-110660 IssueID: TS-R-DF-110663 IssueID: TS-R-DF-110664 Change-Id: I0c7022c0c6e09e54f1b390deb1fb0df27ece4a38 |
#28 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
159218 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP:MCU: Modify the standard value of overvoltage and undervoltage Since the hard test test found that the voltage value of overvoltage and undervoltage is inaccurate, after measuring the accurate value with a multimeter, the value set at the time of overvoltage and undervoltage is reset according to the value of the multimeter. Bin version: V0.0.2 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111421 Change-Id: I3fd7ca9228e844cacd18f483458061fd19a0b354 |
#29 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
159244 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | scm@thundersoft.com |
BSP:MCU: Modify the standard value of overvoltage and undervoltage Since the hard test test found that the voltage value of overvoltage and undervoltage is inaccurate, after measuring the accurate value with a multimeter, the value set at the time of overvoltage and undervoltage is reset according to the value of the multimeter. Bin version: V0.0.2 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111421 Change-Id: Ied8442b138f7781a70e4264bd1d7b2b6c1d55ef3 |
#30 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
160640 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP:MCU: Modify the overvoltage and undervoltage voltage values Modify the overvoltage and undervoltage voltage values: Overvoltage: more than 16.7V, recovery: less than 16.3V; Undervoltage: below 8.4V, recovery: above 8.8V Bin version: V0.0.4 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111421 Change-Id: Ide842c61429108636a33de5a4d46f257b0ed9646 |
#31 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
160831 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | scm@thundersoft.com |
BSP:MCU: Modify the overvoltage and undervoltage voltage values Modify the overvoltage and undervoltage voltage values: Overvoltage: more than 16.7V, recovery: less than 16.3V; Undervoltage: below 8.4V, recovery: above 8.8V Bin version: V0.0.4 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111421 Change-Id: Ic16c7076031ed6fc17656bb222c094dd6c165036 |