测试 Test-IT #110867: V1.0测试功能汇总
测试 Test-IT #110877: BSP-BVT测试-MCU
【BSP】【EVT】【MCU】【必现】MCU升级完成后,未自动掉电重启
Status: | CLOSED | Start date: | 2022-08-24 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | SZ BSP-徐季源 | % Done: | 100% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0.0.0.20220824_alpha_private_userdebug | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Bring Up Test | Root cause: |
Description
前置条件:
1、MCU和SOC端串口通信已调通
2、板子为新的硬件改动过的
3、mcu的bin文件已经push到对应目录
操作步骤:
1、手动安装McuUpdate.apk
2、启动McuUpgrade,点击绑定串口服务后等待5s,再次点击发送请求升级指令
3、shell内执行logcat | grep -iE "UPG-|uart"查看升级log
实际结果:
1、mcu升级完成后,不会自动掉电重启
预期结果:
1、mcu升级完成后,可以自动掉电重启
History
#1 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Priority changed from Normal to High
#2 Updated by SZ BSP-徐季源 almost 3 years ago
- Status changed from New to RESOLVED
- % Done changed from 0 to 100
现版本使 865 关机(例如,adb reboot )可以触发 MCU 重启。
#3 Updated by SZTS_TEST 邹涛 almost 3 years ago
0.0.0.20220830_alpha_private_userdebug 版本验证问题已经修复
#4 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Status changed from RESOLVED to VERIFIED
#5 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Status changed from VERIFIED to CLOSED
#6 Updated by CD TPM-申艳艳 almost 3 years ago
- Category set to BSP