Bug #111489

测试 Test-IT #110867: V1.0测试功能汇总

测试 Test-IT #110877: BSP-BVT测试-MCU

【BSP】【EVT】【MCU】【偶现一次】DUT处于开机状态下,断开电源开关后再次打开电源电源开关,板子无法正常启动;

Added by SZTS_TEST 邹涛 almost 3 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2022-08-26
Priority:HighDue date:
Assignee:SZTS_TEST 邹涛% Done:

0%

Category:BSP
Target version:-
Need_Info:-- Found Version:0.0.0.20220825_alpha_private_userdebug
Resolution:-- Degrated:--
Severity:Critical Verified Version:
Reproducibility:Rarely Fixed Version:
Test Type:Bring Up Test Root cause:

Description

前置条件:
1、DUT各模块功能正常且处于开机状态

操作步骤:
1、关闭直流电源开关
2、再次打开直流电源开关,查看板子和屏幕状态

实际结果:
1、板子无法正常启动,电流显示9ma
2、重新用E1烧录MCU后,板子可以正常启动

预期结果:
1、板子可以正常启动

History

#1 Updated by SZ BSP-徐季源 almost 3 years ago

  • Status changed from New to NEED_INFO
  • Assignee changed from SZ BSP-徐季源 to SZTS_TEST 邹涛

只出现过一次的问题,研发这边是没法解的。给的流程,只有断电和上电两步,研发也有很多开发任务,不可能花时间去做这种概率极低的压力测试。至少测试那边应该测试出一种复现概率超过十分之一的方法

#2 Updated by CD TPM-申艳艳 almost 3 years ago

  • Category set to BSP

#3 Updated by SZTS_TEST 邹涛 over 2 years ago

release分支1011号userdebug版本,验证断开/打开电源开关30次,板子可以正常启动,无异常;后续版本继续压测

#4 Updated by SZTS_TEST 邹涛 over 2 years ago

release分支1014号userdebug版本验证,断开/打开电源开关30次,未复现该问题。已跟踪三个版本,先关闭该bug

#5 Updated by SZTS_TEST 邹涛 over 2 years ago

  • Status changed from NEED_INFO to RESOLVED

#6 Updated by SZTS_TEST 邹涛 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

#7 Updated by SZTS_TEST 邹涛 over 2 years ago

  • Status changed from VERIFIED to CLOSED

Also available in: Atom PDF