Bug #111720
【Figure】【EVT】【EMC】CI02 瞬态耦合抗扰度:Pulse 1fail, 在施加干扰期间,样机断电重启,停止施加干扰后,通过手动操作才能恢复以下功能:1.A2B, 2网口Ping, 3. BT/WIFI 连接。不满足标准要求的自动恢复功能的要求
Status: | CLOSED | Start date: | 2022-09-05 | |
---|---|---|---|---|
Priority: | High | Due date: | 2022-10-31 | |
Assignee: | SZ HW Test-曾小文 | % Done: | 0% | |
Category: | 依赖软件规避的bug | |||
Target version: | 依赖硬件的bugList | |||
Need_Info: | -- | Found Version: | 2022.08.25 | |
Resolution: | FIXED | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: | wifi自动连接进行修改
网络共存和wifi连接做了修改 |
Description
CI02 瞬态耦合抗扰度:Pulse 1fail, 在施加干扰期间,样机断电重启,停止施加干扰后,通过手动操作才能恢复以下功能:1.A2B, 2网口Ping, 3. BT/WIFI 连接。不满足标准要求的自动恢复功能的要求
History
#1 Updated by CD TPM-申艳艳 almost 3 years ago
- Category set to EE
#2 Updated by SZ HW Test-曾小文 almost 3 years ago
- Category changed from EE to BSP
- Assignee set to CD BSP-唐金泽
硬件确认这为软件问题,需要优化软件
#3 Updated by CD BSP-唐金泽 almost 3 years ago
- Assignee changed from CD BSP-唐金泽 to SZ HW Test-曾小文
请问,CI02 瞬态耦合抗扰度 是做什么操作?
通过手动操作才能恢复以下功能,进行什么手动操作?
硬件确认这为软件问题:
可以提供一些硬件判定的细节吗?
#5 Updated by SZ HW Test-曾小文 almost 3 years ago
- Assignee changed from SZ HW Test-曾小文 to SZ-硬件二组_SD3 王苗
#6 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from SZ-硬件二组_SD3 王苗 to CD BSP-陈杰
目前存在问题1.以太网连接下,重启机器需要wifi自动连接;2.CAN需要自动连接而且数据自动收发;软件办公室自测OK后,去实验室复测
#7 Updated by CD BSP-陈杰 over 2 years ago
- Assignee changed from CD BSP-陈杰 to SZ-硬件二组_SD3 王苗
目前已经完成wifi和以太网共存功能,并已经测试成功。can功能目前测试能自动连接,并实现收发。需注意,使用canfd工具的时候,当设备断电时,不能点击自动发送,待设备上电,才能进行自动发送,原因是can盒子发送一次超时后,就需要断开连接在进行连接。
#8 Updated by IOT-SP-TEST 刘颖 over 2 years ago
- Due date changed from 2022-09-26 to 2022-10-31
- Target version set to 依赖硬件的bugList
TO 王成,
1、请用最新版本验证,当WiFi和以太网共存时,WiFi是否可以自动连接;需要的功能是WiFi可以自动连接。
2、如果验证OK,请将此问题转给曾小文,最终在实验室确认。
#9 Updated by CD BSP-唐金泽 over 2 years ago
- Category changed from BSP to 依赖软件规避的bug
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文
#10 Updated by CD BSP-唐金泽 over 2 years ago
- Status changed from RESOLVED to VERIFIED
- Resolution changed from -- to FIXED
- Root cause set to wifi自动连接进行修改 网络共存和wifi连接做了修改
#11 Updated by SZ HW Test-曾小文 over 2 years ago
待EVT2样机在实验室复测OK后再关闭BUG
#12 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED
EVT2用可自动连接的CANOE,以及软件版本可自动连接WiFi,CAN,复测PASS