Bug #111733

【Figure】【EVT】【电气性能】E05 瞬态欠电压:试验中,WiFi,蓝牙,视频和以太网功能失效,试验后,重新上电操作,WiFi,蓝牙,视频和以太网功能正常。

Added by 项目二组_SD3 曾小文 almost 3 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2022-09-05
Priority:HighDue date:
Assignee:SZ HW Test-曾小文% Done:

100%

Category:BSP
Target version:依赖硬件的bugList
Need_Info:-- Found Version:2022.08.25
Resolution:-- Degrated:--
Severity:Major Verified Version:
Reproducibility:Every time Fixed Version:
Test Type:Release Test Root cause:

Description

过程中样机中断工作,试验后,重新上电,运行操作指令,功能正常。

History

#1 Updated by CD TPM-申艳艳 almost 3 years ago

  • Category set to EE

#2 Updated by SZ HW Test-曾小文 almost 3 years ago

  • Subject changed from 【Figure】【EVT】【电气性能】过程中样机中断工作,试验后,重新上电,运行操作指令,功能正常。 to 【Figure】【EVT】【电气性能】E05 瞬态欠电压:试验中,WiFi,蓝牙,视频和以太网功能失效,试验后,重新上电操作,WiFi,蓝牙,视频和以太网功能正常。

#3 Updated by IOT-SP-TEST 刘颖 almost 3 years ago

  • Assignee changed from SZ-硬件二组_SD3 王苗 to CD BSP-杜磊

Class A,OS无需要记忆,MCU修改软件后验证;

#4 Updated by CD TPM-申艳艳 almost 3 years ago

  • Category changed from EE to BSP

Hi 杜磊,
这个用来跟踪BSP 相关问题,谢谢。

#5 Updated by 物联网项目组-RD3_CDTS 周飞 almost 3 years ago

  • Target version set to 依赖硬件的bugList

#6 Updated by CD BSP-杜磊 over 2 years ago

  • Assignee changed from CD BSP-杜磊 to CD BSP-陈杰

#7 Updated by CD BSP-陈杰 over 2 years ago

  • Assignee changed from CD BSP-陈杰 to SZ-硬件二组_SD3 王苗
  • % Done changed from 0 to 100

目前已经通过实验室测试。

#8 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago

  • Status changed from New to RESOLVED
  • Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文

修改软件测试PASS,硬测确认回归。

#9 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

12V风扇改成5V风扇,增加记忆功能后,王苗在中认联实验室复测PASS

#10 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from VERIFIED to CLOSED

Also available in: Atom PDF