Bug #111734
【Figure】【EVT】【电气性能】E06 电压缓降缓升:试验中,电压下降到 9.6V 时,WiFi,蓝牙,视频和以太网功能失效,电压上升恢复到 10.6V 时,屏幕启动,以太网和视频功能需要重新触发启动,试验后,重新上电操作,WiFi,蓝牙,视频和以太网功能正常。
Status: | CLOSED | Start date: | 2022-09-05 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | SZ HW Test-曾小文 | % Done: | 100% | |
Category: | BSP | |||
Target version: | 依赖硬件的bugList | |||
Need_Info: | -- | Found Version: | 2022.08.25 | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: | 由于原来MCU代码存在的问题,目前已经正常修复 |
Description
E06 电压缓降缓升:过程中样机中断工作,低压不能工作,无法自己恢复
History
#1 Updated by 项目二组_SD3 曾小文 almost 3 years ago
- Assignee set to SZ-硬件二组_SD3 王苗
#2 Updated by CD TPM-申艳艳 almost 3 years ago
- Category set to EE
#3 Updated by SZ HW Test-曾小文 almost 3 years ago
- Subject changed from 【Figure】【EVT】【电气性能】E06 电压缓降缓升:过程中样机中断工作,低压不能工作,无法自己恢复 to 【Figure】【EVT】【电气性能】E06 电压缓降缓升:试验中,电压下降到 9.6V 时,WiFi,蓝牙,视频和以太网功能失效,电压上升恢复到 10.6V 时,屏幕启动,以太网和视频功能需要重新触发启动,试验后,重新上电操作,WiFi,蓝牙,视频和以太网功能正常。
#4 Updated by IOT-SP-TEST 刘颖 almost 3 years ago
- Assignee changed from SZ-硬件二组_SD3 王苗 to CD TPM-申艳艳
Class C需要记忆,软件OS需要做记忆
#5 Updated by CD TPM-申艳艳 almost 3 years ago
- Assignee changed from CD TPM-申艳艳 to CD BSP-陈杰
Hi 陈杰,
这个问题用来跟踪 MCU 相关问题,谢谢。
#6 Updated by CD TPM-申艳艳 almost 3 years ago
- Category changed from EE to BSP
#7 Updated by CD BSP-陈杰 almost 3 years ago
- File FigureApp.mot added
- % Done changed from 0 to 80
目前已经完成电压保护功能,还需要AF完成记忆功能,等待AF完成后,还需要进行联合调试。
#8 Updated by 物联网项目组-RD3_CDTS 周飞 almost 3 years ago
- Target version set to 依赖硬件的bugList
#9 Updated by CD BSP-陈杰 over 2 years ago
- File FigureV0.0.1.20221013.1.mot added
- Status changed from New to RESOLVED
- % Done changed from 80 to 100
- Resolution changed from -- to FIXED
- Degrated changed from -- to No
- Root cause set to 由于原来MCU代码存在的问题,目前已经正常修复
MCU使用的文件为:
FigureV0.0.1.20221013.1.mot
SOC版本:
可以使用最新版本进行测试。
实验室测试已经通过。
#10 Updated by CD BSP-陈杰 over 2 years ago
- Assignee changed from CD BSP-陈杰 to SZ HW Test-曾小文
#11 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
12V风扇改成5V风扇,增加记忆功能后,王苗在中认联实验室复测PASS
#12 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED
#13 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
152609 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP:MCU: MCU code buring up, storage, and feature integration This commit protects the following functions: 1. Buring up of MCU code 2. Solve the power-on and power-on sequence bug 3. Increase the voltage protection function 4. MCU firmware upgrade function TC-RID: 1201-0102701 TC-RID: 1201-0102703 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111416 IssueID: TS-R-BUG-111734 IssueID: TS-R-BUG-111732 IssueID: TS-R-BUG-112002 IssueID: TS-R-DF-111421 IssueID: TS-R-DF-112099 IssueID: TS-R-DF-110660 IssueID: TS-R-DF-110663 IssueID: TS-R-DF-110664 Change-Id: Iacb3bbd40b9278405f21f5d34d741dfe08c3c4ff |
#14 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
152787 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP: MCU: Add firmware for MCU programming and upgrade The firmware version information is V0.0.1, which is the initial version. Implementation function: 1. Increase the power-on sequence 2. Increase the voltage protection function 3. Add version information TC-RID: 1201-0102701 TC-RID: 1201-0102703 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111416 IssueID: TS-R-BUG-111734 IssueID: TS-R-BUG-111732 IssueID: TS-R-BUG-112002 IssueID: TS-R-DF-111421 IssueID: TS-R-DF-112099 IssueID: TS-R-DF-110660 IssueID: TS-R-DF-110663 IssueID: TS-R-DF-110664 Change-Id: I047b1483f36d87a7a080b1470eb836cbc620a06e |
#15 Updated by CD FW-王伟 over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
154928 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | jie.chen@thundersoft.com |
BSP:MCU: Functional integration version of the MCU This version contains the following functions: 1.Improve the overvoltage protection function and increase the over-voltage protection communication with the MMU; 2.Improve the function of power-on and power-up sequence, and fix the problem that the boot screen is not displayed; 3.increase the can communication through, currently only open the can's transceiver, there is no integration of other can's functions. TC-RID: 1201-0102701 TC-RID: 1201-0102703 TC-RID: 1201-0102704 IssueID: TS-R-BUG-111416 IssueID: TS-R-BUG-111734 IssueID: TS-R-BUG-111732 IssueID: TS-R-BUG-112002 IssueID: TS-R-DF-111421 IssueID: TS-R-DF-112099 IssueID: TS-R-DF-110660 IssueID: TS-R-DF-110663 IssueID: TS-R-DF-110664 Change-Id: I0c7022c0c6e09e54f1b390deb1fb0df27ece4a38 |