Bug #114545

【Figure】【EVT2】【EMC】RI01 电磁辐射抗扰度(BCI):CBCI 2MHz CAN通讯断开,无法自动恢复,4-8MHz以太网断开可自动恢复,8MHz以后以太网断开无法自动恢复;DBCI 800k-2MHz,CAN通信持续报错,3.7-5.4MHz;8M以后以太网断开无法自动恢复。 3.RI02 电场辐射抗扰度(ALSE)

Added by SZ HW Test-曾小文 over 2 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2022-12-14
Priority:HighDue date:2023-01-20
Assignee:SZ HW Test-曾小文% Done:

0%

Category:EE
Target version:-
Need_Info:-- Found Version:FlatBuild_VX1_MCE_xx.xx_FSE.D.userdebug.0.0.0.20221024.alpha.zip
Resolution:-- Degrated:--
Severity:Normal Verified Version:
Reproducibility:Frequently Fixed Version:
Test Type:Release Test Root cause:

Description

EVT1复测PASS,EVT2标准已加严复测fail

History

#1 Updated by SZ HW Test-曾小文 over 2 years ago

  • Category set to EE

#2 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago

  • Due date set to 2023-01-20
  • Status changed from New to NEED_INFO

已经找到一个70M-90M 共模 150mm有个点以太网会断开,185mA 阈值 。CBCI 750mm 260M点以太网会断开,需要找阈值。

#3 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago

  • Status changed from NEED_INFO to ASSIGNED
  • Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文

BCI实验在以太网接口增加LPF滤波器和5pf电容滤波,用EMC新标准复测在80M附近阈值185mA和260M附近阈值160mA;DBCI PASS,不接光转测试,同时以太网转接板接GND。客户EMC工程师接受测试阈值结果。CAN测试接光转没有报错。手持发射机800M复测不复现问题,PV客户同意不复测手持发射机。

#4 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from ASSIGNED to RESOLVED

#5 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

#6 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from VERIFIED to CLOSED

#7 Updated by SZ HW Test-曾小文 over 2 years ago

  • Subject changed from 【Figure】【EVT2】【EMC】RI01 电磁辐射抗扰度(BCI):CBCI 2MHz CAN通讯断开,无法自动恢复,4-8MHz以太网断开可自动恢复,8MHz以后以太网断开无法自动恢复;DBCI 800k-2MHz,CAN通信持续报错,3.7-5.4MHz;8M以后以太网断开无法自动恢复。 3.RI04 手持发射机抗扰度:加800MHz 干扰信号,以太网会断开。 to 【Figure】【EVT2】【EMC】RI01 电磁辐射抗扰度(BCI):CBCI 2MHz CAN通讯断开,无法自动恢复,4-8MHz以太网断开可自动恢复,8MHz以后以太网断开无法自动恢复;DBCI 800k-2MHz,CAN通信持续报错,3.7-5.4MHz;8M以后以太网断开无法自动恢复。 3.RI02 电场辐射抗扰度(ALSE)

Also available in: Atom PDF