Bug #114546
【Figure】【EVT2】【EMC】RI04 手持发射机抗扰度:加800MHz 干扰信号,以太网会断开。
Status: | CLOSED | Start date: | 2022-12-14 | |
---|---|---|---|---|
Priority: | High | Due date: | 2023-01-20 | |
Assignee: | SZ HW Test-曾小文 | % Done: | 0% | |
Category: | EE | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | FlatBuild_VX1_MCE_xx.xx_FSE.D.userdebug.0.0.0.20221024.alpha.zip | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Frequently | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
EVT2客户已加严测试标准
History
#1 Updated by SZ HW Test-曾小文 over 2 years ago
- Category set to EE
#2 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Due date set to 2023-01-20
在深圳中认加路由器复测没有复现,需要SGS那边复测验证。
#3 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Status changed from New to NEED_INFO
需要SGS那边复测验证,实验室给出的时间是本周20日完成。
#4 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Status changed from NEED_INFO to RESOLVED
- Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文
在深圳中认实验室复测800M频点,没有异常。结果与客户沟通,客户认可,PV EMC测试计划也不测试这手持发射这一项目。
#5 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#6 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED