Bug #114673
【Figure】【EVT2】【EMC】CI01 瞬态传导抗扰度:pulse1和2b 需要手动恢复以太网连接。
Status: | CLOSED | Start date: | 2022-12-19 | |
---|---|---|---|---|
Priority: | Normal | Due date: | 2023-01-20 | |
Assignee: | SZ HW Test-曾小文 | % Done: | 0% | |
Category: | EE | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | FlatBuild_VX1_MCE_xx.xx_FSE.D.userdebug.0.0.0.20221024.alpha | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
EVT1测试PASS,EV2 EMC客户已加严测试标准。
History
#1 Updated by SZ HW Test-曾小文 over 2 years ago
- Category set to EE
#2 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Due date set to 2023-01-20
- Status changed from New to ASSIGNED
- Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文
苏州SGS实验室已经验证加路由器后复测可以PASS.测试复验证。
#3 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from SZ HW Test-曾小文 to SZ-硬件二组_SD3 王苗
硬件请注明解决方法
#4 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文
苏州SGS实验室加路由器后ping IP 方式 ,重新布置测试环境,测试PASS,验证OK。
#5 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#6 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED