Bug #114955

【BSP】【EVT2】【FOTA】板端中断wifi,下载包断开后不会自动重链下载包

Added by CDTS_TEST 刘勇 over 2 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2022-12-30
Priority:NormalDue date:
Assignee:CD BSP 叶鹏 % Done:

0%

Category:BSP
Target version:-
Need_Info:-- Found Version:FlatBuild_HH_VX1_MCE_FSE.M.D.user.01.00.X101.202212140521
Resolution:-- Degrated:--
Severity:Normal Verified Version:
Reproducibility:Every time Fixed Version:
Test Type:IT Root cause:需求取消,关闭处理

Description

【前提条件】
1.中控环境搭建好
2.中控环境中有全量包(FTP中文件名为:merged-qssi_figure-ota.zip )

【测试步骤】
2.
3.中控通过网线链接路由,DUT通过wifi 链接路由
4.中控IP:192.168.0.2 ,DUT-IP:192.168.0.18
5.进入终端,cd ~/server/目录,并运行命令
sudo ./run_https.sh
sudo ./run_orch.sh
adb shell logcat > logcat.txt
6.待功能启动
7.选择功能2(Download PACKAGE)
输入"2"->按"回车" ->输入 "1"->输入"update.zip"
8.等待下载,断开DUT的wifi
9.等待2秒后,重新链接wifi

【期望结果】
8.断开包下载
9.链接wifi,DUT的ip地址正确后,会自动下载FOTA包

【实际结果】
9.链接wifi,DUT的ip地址正确后,不会自动下载FOTA包

History

#1 Updated by CD BSP 叶鹏 over 2 years ago

博世FOTA接口取消

#2 Updated by CDTS-TEST 周婷 over 2 years ago

  • Status changed from New to CLOSED
  • Root cause set to 需求取消,关闭处理

博世fota接口取消,此问题暂时先处理处理

Also available in: Atom PDF