Bug #115770

【Figure】【EVT3】【RF】[WiFi RSSI]常温条件下,WiFi RSSI测试中,2.4 GWiFi 11g CH7 54M中存在Power Level偏高问题,标准值:-55±3dBm,最高值:-50dBm,不符合企标。

Added by SZ HW Test-曾小文 over 2 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2023-02-02
Priority:HighDue date:
Assignee:SZ HW Test-曾小文% Done:

0%

Category:EE
Target version:-
Need_Info:-- Found Version:12月20号
Resolution:-- Degrated:--
Severity:Major Verified Version:
Reproducibility:Frequently Fixed Version:
Test Type:Release Test Root cause:

Description

[WiFi RSSI]常温条件下,WiFi RSSI测试中,2.4 GWiFi 11g CH7 54M中存在Power Level偏高问题,标准值:-55±3dBm,最高值:-50dBm,不符合企标。

History

#1 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from New to RESOLVED

这个板子前面测非信令Tx的时候,为了硬测能使用自动化工具,我通过改BDF把两个链路都开并导入到板子里。而测试RSSI的时候为信令模式,需要把CH1关闭,也就是把正式的BDF文件刷回去,否则RSSI会偏移,导致fail。

#2 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

复测PASS

#3 Updated by SZ HW Test-曾小文 over 2 years ago

  • Status changed from VERIFIED to CLOSED
  • Assignee changed from 硬件二组_SD3 陈澍锴 to SZ HW Test-曾小文

Also available in: Atom PDF