Bug #116315
【BSP】【EVT3】【ST】【MCU】A样机与中控连接启动后,无法获取MCU版本号
Status: | CLOSED | Start date: | 2023-02-16 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | BSP | |||
Target version: | VC1_FSE_0078_20230228 | |||
Need_Info: | -- | Found Version: | 0068 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | https://dev.thundercomm.com/gerrit/c/Pre_figure/mcu/+/183882 | |
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | ST | Root cause: | 此bug会引起MCU在升级过程中,如果掉电,则无法启动的问题;
原因是:升级擦除的片区和运行的片区一致导致。 |
Description
【前提条件】
None
【测试步骤】
1. 设备正常开机与中控正常连接
2. 获取MCU版本号
【预期结果】
2 可以正常获取MCU版本号
【实际结果】
2 无法获取MCU版本号
History
#1 Updated by CD TPM-王祥林 over 2 years ago
- Target version set to VC1_FSE_0078_20230228
#2 Updated by CD BSP-杜磊 over 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD BSP-杜磊 to CD BSP-陈杰
请帮忙分析此问题
#3 Updated by CD BSP-陈杰 over 2 years ago
- File FigureV0.1.0.mot added
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD BSP-陈杰 to CDTS_TEST 王成
- % Done changed from 0 to 100
- Verified Version set to https://dev.thundercomm.com/gerrit/c/Pre_figure/mcu/+/183882
- Root cause set to 此bug会引起MCU在升级过程中,如果掉电,则无法启动的问题; 原因是:升级擦除的片区和运行的片区一致导致。
麻烦进行MCU的升级压力测试,观察是否还会复现该问题
#4 Updated by CD BSP-陈杰 over 2 years ago
使用MCU版本为V0.1.0的user版本配合上传的mot文件测试一下,设备会不会进行mcu升级
#5 Updated by CDTS_TEST 王成 over 2 years ago
- Assignee changed from CDTS_TEST 王成 to 移动测试一组_CDTS 刘强
#6 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from RESOLVED to VERIFIED
根据MCU异常断电压测结果:https://thundersoft.feishu.cn/sheets/shtcn5ImqRt1IhgQPZiHG2kCNxe?sheet=NxPTfb
验证通过,关闭此问题
#7 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from VERIFIED to CLOSED