Bug #116878
【AF】【EVT3】【ST】【屏保】【偶现】MCU 过压保护反复测试过程中出现设备开机后,开机动画过后第一个界面是屏保设置,而不是homescreen
Status: | CLOSED | Start date: | 2023-03-10 | |
---|---|---|---|---|
Priority: | High | Due date: | 2023-03-17 | |
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | CD-APP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0078 | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | 2023-03-17 | |
Test Type: | ST | Root cause: | 编码问题 |
Description
【前提条件】
使用稳压电源进线供电
【测试步骤】
1. 烧写正常版本后开机
2. 在开机引导界面或开机动画界面升压至19V
3. 触发过压保护后,重新上电开机,执行恢复出厂
4. 在开机动画和开机引导界面升压
5. 反复压测
【预期结果】
2&4 均能触发过压保护
5. 可以正常开机
【实际结果】
5. 会偶现开机动画过后第一个界面是屏保设置,而不是homescreen
Related issues
History
#1 Updated by CD TPM-王祥林 over 2 years ago
- Category changed from CD-FW to CD-APP
- Assignee changed from CD TPM-王祥林 to CD APP-王营
#2 Updated by CD APP-王营 over 2 years ago
- Status changed from New to ASSIGNED
■ Current conclusion
问题已解决,待验证
■ My analysis
压测时间过长导致屏保模式触发,屏保Activity被保存,过压保护触发后重启,Launcher拉起了保存的屏保应用,处理方式为取消屏保应用的保存。
■Submit URL
https://dev.thundercomm.com/gerrit/c/general/platform/packages/apps/Launcher3/+/187146
#3 Updated by CD APP-王营 over 2 years ago
- % Done changed from 0 to 50
- Resolution changed from -- to FIXED
■ Current conclusion
问题已处理,验证中
■ My analysis
在压测过程中,触发过压保护之前保存了ScreenSaver的包名和Activity的名称,过压保护重启后此页面被拉起,ScreenSaver在过压保护的需求中是不需要保存的,结合当前业务场景,如果启动页面为ScreenSaver则存入空页面。
■Submit URL
https://dev.thundercomm.com/gerrit/c/general/platform/packages/apps/Launcher3/+/187146
#4 Updated by IoT scm over 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
187146 | general/platform/packages/apps/Launcher3 | Pre_figure_turbox-c2130c-la1.1-qssi12-dev | ying.wang@thundersoft.com |
AF: Launcher: Fix overvoltage protection bug 1.Should not save the screensaver app when overvoltage protection triggered. TC-RID: 0301-0300601 IssueID: TS-R-BUG-116878 Change-Id: If8799b91fb87ba58073ca0956491b12d17dce102 |
#5 Updated by CD APP-王营 over 2 years ago
- Due date set to 2023-03-17
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD APP-王营 to 移动测试一组_CDTS 刘强
- % Done changed from 50 to 100
- Degrated changed from -- to No
- Fixed Version set to 2023-03-17
- Root cause set to 编码问题
#6 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from RESOLVED to VERIFIED
验证版本:FlatBuild_HH_MCE_FSE.M.D.user.01.00.C101.202303191230
验证结果:验证10次,未复现
#7 Updated by 移动测试一组_CDTS 刘强 over 2 years ago
- Status changed from VERIFIED to CLOSED
#8 Updated by CD BSP-杜磊 about 2 years ago
- Subject changed from 【BSP】【EVT3】【ST】【屏保】【偶现】MCU 过压保护反复测试过程中出现设备开机后,开机动画过后第一个界面是屏保设置,而不是homescreen to 【AF】【EVT3】【ST】【屏保】【偶现】MCU 过压保护反复测试过程中出现设备开机后,开机动画过后第一个界面是屏保设置,而不是homescreen