Bug #116878

【AF】【EVT3】【ST】【屏保】【偶现】MCU 过压保护反复测试过程中出现设备开机后,开机动画过后第一个界面是屏保设置,而不是homescreen

Added by 移动测试一组_CDTS 刘强 over 2 years ago. Updated about 2 years ago.

Status:CLOSEDStart date:2023-03-10
Priority:HighDue date:2023-03-17
Assignee:移动测试一组_CDTS 刘强% Done:

100%

Category:CD-APP
Target version:-
Need_Info:-- Found Version:0078
Resolution:FIXED Degrated:No
Severity:Major Verified Version:
Reproducibility:Occasionally Fixed Version:2023-03-17
Test Type:ST Root cause:编码问题

Description

【前提条件】
使用稳压电源进线供电

【测试步骤】
1. 烧写正常版本后开机
2. 在开机引导界面或开机动画界面升压至19V
3. 触发过压保护后,重新上电开机,执行恢复出厂
4. 在开机动画和开机引导界面升压
5. 反复压测

【预期结果】
2&4 均能触发过压保护
5. 可以正常开机

【实际结果】
5. 会偶现开机动画过后第一个界面是屏保设置,而不是homescreen

20230310-183618.jpg (103 KB) 移动测试一组_CDTS 刘强, 2023-03-10 18:38

test.txt Magnifier (3.16 MB) 移动测试一组_CDTS 刘强, 2023-03-10 18:38

20230310-183618

Related issues

Related to Figure - Bug #116883: 【AF】【EVT3】【ST】【Display】【偶现】使用稳压电源进行过压保护测试断电后,重新上电,开机后出显示一... CLOSED 2023-03-11 2023-03-17

History

#1 Updated by CD TPM-王祥林 over 2 years ago

  • Category changed from CD-FW to CD-APP
  • Assignee changed from CD TPM-王祥林 to CD APP-王营

#2 Updated by CD APP-王营 over 2 years ago

  • Status changed from New to ASSIGNED

■ Current conclusion
问题已解决,待验证
■ My analysis
压测时间过长导致屏保模式触发,屏保Activity被保存,过压保护触发后重启,Launcher拉起了保存的屏保应用,处理方式为取消屏保应用的保存。
■Submit URL
https://dev.thundercomm.com/gerrit/c/general/platform/packages/apps/Launcher3/+/187146

#3 Updated by CD APP-王营 over 2 years ago

  • % Done changed from 0 to 50
  • Resolution changed from -- to FIXED

■ Current conclusion
问题已处理,验证中
■ My analysis
在压测过程中,触发过压保护之前保存了ScreenSaver的包名和Activity的名称,过压保护重启后此页面被拉起,ScreenSaver在过压保护的需求中是不需要保存的,结合当前业务场景,如果启动页面为ScreenSaver则存入空页面。
■Submit URL
https://dev.thundercomm.com/gerrit/c/general/platform/packages/apps/Launcher3/+/187146

#4 Updated by IoT scm over 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
187146 general/platform/packages/apps/Launcher3 Pre_figure_turbox-c2130c-la1.1-qssi12-dev
AF: Launcher: Fix overvoltage protection bug
1.Should not save the screensaver app when overvoltage protection triggered.
TC-RID: 0301-0300601
IssueID: TS-R-BUG-116878
Change-Id: If8799b91fb87ba58073ca0956491b12d17dce102

#5 Updated by CD APP-王营 over 2 years ago

  • Due date set to 2023-03-17
  • Status changed from ASSIGNED to RESOLVED
  • Assignee changed from CD APP-王营 to 移动测试一组_CDTS 刘强
  • % Done changed from 50 to 100
  • Degrated changed from -- to No
  • Fixed Version set to 2023-03-17
  • Root cause set to 编码问题

#6 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

验证版本:FlatBuild_HH_MCE_FSE.M.D.user.01.00.C101.202303191230
验证结果:验证10次,未复现

#7 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

  • Status changed from VERIFIED to CLOSED

#8 Updated by CD BSP-杜磊 about 2 years ago

  • Subject changed from 【BSP】【EVT3】【ST】【屏保】【偶现】MCU 过压保护反复测试过程中出现设备开机后,开机动画过后第一个界面是屏保设置,而不是homescreen to 【AF】【EVT3】【ST】【屏保】【偶现】MCU 过压保护反复测试过程中出现设备开机后,开机动画过后第一个界面是屏保设置,而不是homescreen