Bug #117236

【BSP】【VC1】【Touch】TP更新固件后TP无响应

Added by CD BSP-杜磊 over 2 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2023-03-29
Priority:NormalDue date:
Assignee:移动测试一组_CDTS 刘强% Done:

70%

Category:BSP
Target version:VC1_FSE_0090_20230411
Need_Info:-- Found Version:FlatBuild_HH_MCE_FSE.M.R.user.01.00.0086.C102(X102)
Resolution:-- Degrated:--
Severity:Normal Verified Version:
Reproducibility:Every time Fixed Version:
Test Type:ST Root cause:升级完后,reset动作未生效

Description

TP更新不同固件后,出现TP无法使用

History

#1 Updated by CD BSP-杜磊 over 2 years ago

  • Status changed from New to RESOLVED
  • Assignee changed from CD BSP-杜磊 to 移动测试一组_CDTS 刘强
  • % Done changed from 0 to 70
  • Root cause set to 升级完后,reset动作未生效

Hi, 刘强,

请使用3/30的VB版本进行验证
ftp://cdiot@192.168.87.46/Pre_figure/VerifyBuild/Pre_figure_turbox-c2130c-la1.1-qssi12-dev/20230329/202303292109-3130/FlatBuild_HH_MCE_FSE.M.D.user.01.00.C102%28X102%29.202303292109.zip

验证方法:
刷之前老的版本,再刷VB版本,验证TP升级后是否能正常触摸。

Thanks.

#2 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

vb版本验证通过
烧写12月工厂版本全擦
再烧写0086 user不全擦
开机后显示正常,TP可用

#3 Updated by IoT scm over 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
190776 general/kernel/msm-4.19 Pre_figure_turbox-c2130c-la1.1-vendor-dev
BSP:TP: Fix VC1 tp can't work after upgrade FW
Touch's interrupt must be enabled after updating FW
TC-RID: 1201-0100401
IssueID: TS-R-DF-117236
Change-Id: I779ed15a7952940edede52728883b0ab95086184

#4 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

验证版本:FlatBuild_HH_MCE_FSE.M.D.userdebug.01.00.C102.202304020018
验证结果:验证通过

烧写12月工厂版本全擦
再烧写FlatBuild_HH_MCE_FSE.M.D.userdebug.01.00.C102.202304020018不全擦
开机后显示正常,TP可用

#5 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

  • Status changed from VERIFIED to CLOSED