Bug #117376
【AF】【EVT3】【ST】【Settings】当连接一个wifi后,再次点击其他wifi,再输入密码时键盘会出现屏幕误触
Status: | CLOSED | Start date: | 2023-04-10 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 物联网项目组-RD3_CDTS 周飞 | % Done: | 0% | |
Category: | 依赖客户及其供应商解决 | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0089 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | ||
Test Type: | ST | Root cause: | 因网络模块需要移除,前置 BUG 未处理的后续问题。 |
Description
【步骤】
1. 烧写0089版本
2. 开机后执行恢复出厂操作
3. 恢复出厂完成后连接wifi,输入密码
4. 连接一个wifi后,再次直接点击其他wifi,输入密码
5. 当点击R或E时等,不会响应键盘字母输出,会点击到其他地方从而切换界面
【预期结果】
输入正常
【实际结果】
当点击R或E时等,不会响应键盘字母输出,会点击到其他地方从而切换界面
Related issues
History
#1 Updated by CD TPM-王祥林 about 2 years ago
- Assignee changed from CD TPM-王祥林 to CD FW 曹覃刚
#2 Updated by CD FW 曹覃刚 about 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD FW 曹覃刚 to CD FW-廖涛
#3 Updated by CD FW-廖涛 about 2 years ago
- Status changed from ASSIGNED to NEED_INFO
- Assignee changed from CD FW-廖涛 to 移动测试一组_CDTS 刘强
- Root cause set to 因网络模块需要移除,前置 BUG 未处理的后续问题。
■ My analysis
问题的产生是因为上一次输入完成后,键盘未被关闭,再次调起键盘时,键盘无法获取焦点,导致输入穿透键盘。正常情况下,输入完成后,需要关闭键盘,第三方应用针对这种场景的处理方式一样,若存在这种情况,属于第三方应用适配问题,系统无需处理。
网络模块因为最终版本要移除,所以不做处理。参考:https://share.thundersoft.com/redmine/issues/114768
■ Next action
测试评估。
#4 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Assignee changed from 移动测试一组_CDTS 刘强 to CDTS_TEST 王成
Hi,
王成
帮忙内部评估下,如果没问题就关闭这个问题
#5 Updated by CDTS_TEST 王成 about 2 years ago
- Assignee changed from CDTS_TEST 王成 to 物联网项目组-RD3_CDTS 周飞
输入法关联问题,
#6 Updated by CDTS_TEST 王成 about 2 years ago
- Status changed from NEED_INFO to RESOLVED
- Assignee changed from 物联网项目组-RD3_CDTS 周飞 to CDTS_TEST 王成
WIFI模块功能问题,BUG先行关闭,若WIFI模块需求出现变更,需要解决
#7 Updated by CDTS_TEST 王成 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#8 Updated by CDTS_TEST 王成 about 2 years ago
- Status changed from VERIFIED to CLOSED
#9 Updated by CDTS_TEST 王成 about 2 years ago
- Status changed from CLOSED to New
- Assignee changed from CDTS_TEST 王成 to CD TPM-王祥林
麻烦看看这个BUG是否需要再次跟踪处理
#10 Updated by CD TPM-王祥林 about 2 years ago
- Status changed from New to NEED_INFO
- Assignee changed from CD TPM-王祥林 to CDTS_TEST 王成
wifi要被移除,可以不用关注wifi界面的问题。但要测一下除了wifi界面,其他输入框是不是也存在这个问题。
#11 Updated by CDTS_TEST 王成 about 2 years ago
- Category changed from CD-FW to 依赖客户及其供应商解决
- Assignee changed from CDTS_TEST 王成 to 物联网项目组-RD3_CDTS 周飞
输入法合入之后再做验证,排除输入法问题
#12 Updated by CDTS_TEST 王成 almost 2 years ago
- Status changed from NEED_INFO to RESOLVED
WIFI界面整已体隐藏
#13 Updated by CDTS_TEST 王成 almost 2 years ago
- Status changed from RESOLVED to VERIFIED
#14 Updated by CDTS_TEST 王成 almost 2 years ago
- Status changed from VERIFIED to CLOSED