Bug #117498
【IOVDEV-20380】【IOV测试】【VC1】【SORP】【副屏】【实车341】副驾息屏唤醒后,出现文件夹APP收起动效
Status: | CLOSED | Start date: | 2023-04-14 | ||
---|---|---|---|---|---|
Priority: | Normal | Due date: | |||
Assignee: | 物联网测试组_TSCD 王维 | % Done: | 20% | ||
Category: | 依赖客户及其供应商解决 | ||||
Target version: | - | ||||
Need_Info: | -- | Found Version: | 中控版本:03.02.0066.C101
副屏版本:0086 |
||
Resolution: | -- | Degrated: | -- | ||
Severity: | Normal | Verified Version: | |||
Reproducibility: | Occasionally | Fixed Version: | |||
Test Type: | ST | Root cause: | 屏幕唤醒事件较长,导致TP坐标报点会误点击app |
Description
【前提条件】
实车341
【操作步骤】
1.副驾点击息屏-点击屏幕唤醒
【实际结果】
页面出现APP收到文件夹的动效
【期望结果】
正常显示息屏之前的页面
【时间】
4月5号 14:22
【备注】
VIN:LJD8BB3F0P0000341
LOG已经上传云
EE环境
History
#1 Updated by CD FW-程天颖 about 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD FW-程天颖 to CD APP-王营
#2 Updated by CD FW-程天颖 about 2 years ago
- Category changed from CD-FW to BSP
- Assignee changed from CD APP-王营 to CD BSP-杜磊
可能和https://share.thundersoft.com/redmine/issues/117228 有关联,请帮忙分析一下
#3 Updated by CD BSP-杜磊 about 2 years ago
- Status changed from ASSIGNED to NEED_INFO
- Assignee changed from CD BSP-杜磊 to 移动测试一组_CDTS 刘强
- % Done changed from 0 to 20
Hi, 刘强,
请用下次DB验证一下此问题
#4 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Assignee changed from 移动测试一组_CDTS 刘强 to CD BSP-杜磊
验证版本:FlatBuild_HH_MCE_FSE.M.D.userdebug.01.00.C103.202304150126
验证结果:未复现
验证版本:FlatBuild_HH_MCE_FSE.M.D.userdebug.01.00.C103.202304150126
验证结果:验证通过
验证内容:VC和VX板子
1. 点击熄屏-点击亮屏 20次
2. 开机后热插拔 10次
3. 启动过程中热插拔 10次
4. FDR 后点击熄屏-唤醒 10次
初步分析由于之前点击屏幕唤醒比较慢,但是设备已经响应,因此在黑屏时点击屏幕操作到了其他app,因此亮屏时显示了APP收起动效
#5 Updated by CD BSP-杜磊 about 2 years ago
- Assignee changed from CD BSP-杜磊 to 物联网测试组_TSCD 王维
#6 Updated by CD BSP-杜磊 about 2 years ago
- Root cause set to 屏幕唤醒事件较长,导致TP坐标报点会误点击app
#7 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Status changed from NEED_INFO to RESOLVED
#8 Updated by 物联网测试组_TSCD 王维 about 2 years ago
中控版本:0070
副屏版本:0103
新版本修复亮屏慢的bug,目前点击息屏后的副屏正常触发亮屏,没有再复现该现象;还需跟踪2个版本
#9 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Category changed from BSP to 依赖客户及其供应商解决
- Status changed from RESOLVED to NEED_INFO
已验证版本:
0092
0103 VB
0093
非复现该现象,待客户验证
#10 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Status changed from NEED_INFO to RESOLVED
#11 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#12 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Status changed from VERIFIED to CLOSED