Bug #117728
【BSP】【DVT】【MCU】【客户验证】锦江实车:0090 userdebug升级到0094 user后,偶现 锁车副屏不关机问题
Status: | CLOSED | Start date: | 2023-04-28 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0090-0094 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | ||
Test Type: | ST | Root cause: |
Description
前置条件
None
操作步骤:
1.设备烧写0090 userdebug版本
2.OTA升级到0094 user版本
3.中控副屏点击下电关机
预期结果:
副屏关机
实际结果:
副屏不关机
History
#1 Updated by CD TPM-王祥林 about 2 years ago
- Assignee changed from CD TPM-王祥林 to BSP组-RD3_CDTS 陈宙贤
#2 Updated by BSP组-RD3_CDTS 陈宙贤 about 2 years ago
使用EVT 01的硬件板子验证,从0090->0094,从mcu串口中可看到mcu进入了升级流程,也看到完成MCU完成升级的标志3C 08 00 00 FF 85 01 4F 。但从问题车中的日志发现,MCU并未进入升级流程。
下一步先继续看日志,分析原因。
#3 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
198906 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | zhouxian.chen@thundersoft.com |
BSP:MCU: Fix abnormal restart issues during upgrade Modifying abnormal upgrade issues caused by CAN interruption. Currently, the initialization of CAN has been annotated, and further debugging will be carried out according to the requirements of CAN. Bin version: V0.1.6 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: Ic47a5af820265273dff75c3b71eb06db5c464f63 |
#4 Updated by BSP组-RD3_CDTS 陈宙贤 about 2 years ago
V0.1.5已修复kl15开关无效导致副屏不关机问题。
当前bug是由于升级失败引起,当重新升级后,引出升级失败反复重启问题。
当前分析是在升级过程中的CAN中断引起的升级异常。
#5 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
198979 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | scm@thundersoft.com |
BSP:MCU: Fix abnormal restart issues during upgrade Modifying abnormal upgrade issues caused by CAN interruption. Currently, the initialization of CAN has been annotated, and further debugging will be carried out according to the requirements of CAN. Bin version: V0.1.6 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: Ifc106db57b602347c8e6e8ae5db7d06ec3f8e3d3 |
#6 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
198866 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-release_v8.7 | wangxl0510@thundersoft.com |
BSP:MCU: Fix abnormal restart issues during upgrade Modifying abnormal upgrade issues caused by CAN interruption. Currently, the initialization of CAN has been annotated, and further debugging will be carried out according to the requirements of CAN. Bin version: V0.1.6 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: Ifc106db57b602347c8e6e8ae5db7d06ec3f8e3d3 (cherry picked from commit f429cc4a2bc4c3ef12271d822a2b6872db624b0f) |
#7 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
199202 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | wangxl0510@thundersoft.com |
BSP:MCU: Change mcu version from V0.1.6 to V0.1.7 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: I24cc7342c67b569c6c056e5035917c368fd1aede |
#8 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
199285 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-release_v0098 | wangxl0510@thundersoft.com |
BSP:MCU:Update MCU from V0.1.5 to V0.1.7 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: I1584372737e8abcd967a22ff9134234740758160 |
#9 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
199869 | Pre_figure/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | zhouxian.chen@thundersoft.com |
BSP:MCU: Disable CAN Interrupt Before MCU Upgrading Disable CAN Interrupt and ADC Interrupt Before MCU Upgrading. Bin version: V0.1.7 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: Ibb1db63ce47cec545fd9985c10a3fc6ad4edeb28 |
#10 Updated by BSP组-RD3_CDTS 陈宙贤 about 2 years ago
已修改:https://dev.thundercomm.com/gerrit/c/Pre_figure/mcu/+/199869
1.在跳转boot之前禁用CAN中断。MCU版本更新为V0.1.7
#11 Updated by BSP组-RD3_CDTS 陈宙贤 about 2 years ago
- Status changed from New to RESOLVED
- Assignee changed from BSP组-RD3_CDTS 陈宙贤 to 移动测试一组_CDTS 刘强
- % Done changed from 0 to 100
#12 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Subject changed from 【BSP】【DVT】【MCU】锦江实车:0090 userdebug升级到0094 user后,偶现 锁车副屏不关机问题 to 【BSP】【DVT】【MCU】【客户验证】锦江实车:0090 userdebug升级到0094 user后,偶现 锁车副屏不关机问题
#13 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
200283 | general/vendor/tc/mcu | Pre_figure_turbox-c2130c-la1.1-vendor-dev | scm@thundersoft.com |
BSP:MCU: Disable CAN Interrupt Before MCU Upgrading Disable CAN Interrupt and ADC Interrupt Before MCU Upgrading. Bin version: V0.1.7 TC-RID: 1201-0102704 IssueID: TS-R-BUG-117728 Change-Id: Iebfb0eb4b5e40c269713aed736e6b78d42aa87a9 |
#14 Updated by 移动测试一组_CDTS 刘强 almost 2 years ago
- Status changed from RESOLVED to VERIFIED
根据:https://thundersoft.feishu.cn/docx/DdV8dpUz1owXYDxMQrMcf4Lonyh 验证结果且客户近期未出现同件问题,因此关闭
#15 Updated by 移动测试一组_CDTS 刘强 almost 2 years ago
- Status changed from VERIFIED to CLOSED