Bug #117769
【BSP】【EVT3】【ST】【工厂模式】进入工厂模式后,fan没有自动转起来
Status: | CLOSED | Start date: | 2023-05-05 | |
---|---|---|---|---|
Priority: | Normal | Due date: | 2023-05-15 | |
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0095 | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Normal | Verified Version: | FlatBuild_HH_MCE_FSE.M.R.user.01.00.0101.C103(X103) | |
Reproducibility: | Every time | Fixed Version: | 2023-05-17 | |
Test Type: | ST | Root cause: | 功能实现 |
Description
【前提条件】
None
【测试步骤】
1. 烧写0095版本
2. 设备开机到工厂模式选择界面(汽车图片界面)
3. 同时按四个角进入工厂模式
【预期结果】
3.1 进入工厂模式后,fan应该自动旋转,DTC上报正常
3.2 挡住风扇后,报异常code
【实际结果】
3 进入工厂模式后,fan没有自动转起来
kernel.txt Magnifier (346 KB) Delete 移动测
History
#1 Updated by CD TPM-王祥林 about 2 years ago
- Assignee changed from CD TPM-王祥林 to CD BSP 叶鹏
叶鹏
处理一下这个节点的写权限。
java.io.FileNotFoundException: /sys/devices/platform/vendor/vendor:pwm-fan/hwmon/hwmon1/pwm1: open failed: EACCES (Permission denied)
#2 Updated by CDTS-TEST 周婷 about 2 years ago
- Due date set to 2023-05-15
#3 Updated by CD BSP 叶鹏 about 2 years ago
- Status changed from New to RESOLVED
- % Done changed from 0 to 90
#4 Updated by CD BSP 叶鹏 about 2 years ago
- Assignee changed from CD BSP 叶鹏 to CD FW-廖涛
#5 Updated by CD FW-廖涛 about 2 years ago
- Status changed from RESOLVED to ASSIGNED
#6 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
200515 | general/platform/vendor/thundercomm/apps/TCSetupWizard | Pre_figure_turbox-c2130c-la1.1-qssi12-dev | tao.liao@thundersoft.com |
AF:FactoryMode: Add MCU info and modify fun get logical. TC-RID: 1201-0207601 IssueID: TS-R-BUG-117769 Change-Id: I69a376bc746eab2acce114e7fd04a66f250c9aed |
#7 Updated by CD FW-廖涛 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD FW-廖涛 to 移动测试一组_CDTS 刘强
- % Done changed from 90 to 100
- Resolution changed from -- to FIXED
- Degrated changed from -- to No
- Fixed Version set to 2023-05-17
- Root cause set to 功能实现
■ Current conclusion
已处理,代码已入库。
■ My analysis
-
■ Next action
测试验证。
#8 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Status changed from RESOLVED to VERIFIED
- Verified Version set to FlatBuild_HH_MCE_FSE.M.R.user.01.00.0101.C103(X103)
检测逻辑:
进入工厂模式页面,会打开风扇,然后等待 5s ,获取风扇转速,获取完成后关闭风扇;且只获取一次,如果一直停留在页面,风扇转速不会刷新
#9 Updated by 物联网测试组_TSCD 王维 about 2 years ago
- Status changed from VERIFIED to CLOSED