Bug #117853
【IOVDEV-26824】【内部】【VC1】【0072】【台架】【EE环境】【副屏】副屏熄屏后自动点亮
Status: | CLOSED | Start date: | 2023-05-10 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | CDTS_Test 吴诗雨 | % Done: | 0% | |
Category: | 依赖客户及其供应商解决 | |||
Target version: | - | |||
Need_Info: | TEST | Found Version: | 副屏版本:01.00.0094.c103
中控版本:03.02.0078.C101 |
|
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | ST | Root cause: |
Description
【环境信息】EE环境
【问题出现时间】:20230509 17:06
【前提条件】:车机上电, 副屏熄屏
【操作步骤】
1. 中控端使用语音功能,输入指令“副屏亮屏”
2.副屏响应中控的语音指令而亮屏
3.中控退出语音识别,副屏再次通过点击控制中心中的熄屏按钮而熄屏
【实际结果】
副屏在熄屏后会会自动亮屏,手动熄屏后还是会自动亮屏
【期望结果】
副屏熄屏后不会自动亮屏
【车架号】:
【备注】:
副屏log地址:https://ofs.human-horizons.com/#/download/index/LNsgcFDUwH0%3D
【影响版本】:副屏:01.00.0094.c103 中控:03.02.0078.C101
【硬件版本号】:/
【是否能恢复】:
Related issues
History
#1 Updated by CD FW-程天颖 about 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD FW-程天颖 to CDTS_Test 吴诗雨
- Need_Info changed from -- to TEST
Hi,诗雨:
我的中控无法语音控制,不能复现,Tlog里面没有看到关键点日志,需要重新测试,抓取日志,建议adb抓副屏日志。
#2 Updated by CD FW-程天颖 about 2 years ago
- Status changed from ASSIGNED to NEED_INFO
#3 Updated by CDTS_TEST 王成 about 2 years ago
- File 20点41分复现IOVDEV-26824.7z added
- Assignee changed from CDTS_Test 吴诗雨 to CD FW-程天颖
20点41分复测截取adb log。如此问题描述:副屏熄屏情况下,
1. 中控端使用语音功能,输入指令“打开副屏”
2.副屏响应中控的语音指令而亮屏
3.副屏控制中心点击熄屏
现象:副屏熄屏后会自动亮屏。再次进控制中心点击熄屏,副屏熄屏后还是会自动亮屏
#4 Updated by CD FW-程天颖 about 2 years ago
- Category changed from CD-FW to 依赖客户及其供应商解决
- Status changed from NEED_INFO to ASSIGNED
- Assignee changed from CD FW-程天颖 to CDTS_Test 吴诗雨
日志分析:
05-15 20:42:24.452 2236 15269 D RemoteControlService: After desEncrypt json is [{"type":"power","source":0,"token":"n0DhEcGdClTOZQy","value":"click"}]
中控发送电源键事件点亮副屏
05-15 20:42:48.016 2044 15341 D MicroService: Send message to IDCM:SocketMessageBean{businessData='21930', srcService='FSEM_SettingService', destService='IDCM_MultiScreenService', messageType='0', uuid='1684154568010075191', payloadData={"srcService":"FSEM_SettingService","dstService":"IDCM_MultiScreenService","messageType":0,"uuid":1684154568010075191,"methodName":"reportScreenDisplay","parameters":{"reportScreenDisplay":1}}}
副屏点亮屏幕后,给中控上报屏幕状态
05-15 20:42:51.735 2044 15354 D MicroService: Send message to IDCM:SocketMessageBean{businessData='21930', srcService='FSEM_SettingService', destService='IDCM_MultiScreenService', messageType='0', uuid='1684154571733033992', payloadData={"srcService":"FSEM_SettingService","dstService":"IDCM_MultiScreenService","messageType":0,"uuid":1684154571733033992,"methodName":"reportScreenDisplay","parameters":{"reportScreenDisplay":0}}}
副屏上报熄灭副屏
后续中控又发送了息屏电源键时间给副屏,点亮
05-15 20:43:00.046 2236 15381 D RemoteControlService: After desEncrypt json is [{"type":"power","source":0,"token":"n0DhEcGdClTOZQy","value":"click"}]
结论:中控获取到副屏状态改变后,又使用遥控器sdk发送了一次电源键事件打开副屏,需要中控检查语言控制逻辑并修改
建议:1.语音控制使用的遥控器sdk来控制副屏状态,在使用过程中可能会影响遥控器的功能使用,建议通过中控副屏通信有IDCM_MultiScreenService服务,来获取和设置副屏的屏幕状态
#5 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
#6 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#7 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from VERIFIED to CLOSED
#8 Updated by CDTS_TEST 王成 about 2 years ago
Line 192143: 05-18 11:28:10.326 5520 5540 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-query connect co-driver screen
Line 192205: 05-18 11:28:10.526 5520 6571 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-query co-driver screen power status
Line 192241: 05-18 11:28:10.541 5520 6739 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-open co-driver screen
Line 193790: 05-18 11:28:15.346 5520 6739 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-already open co-driver screen
Line 195279: 05-18 11:28:19.550 5520 6687 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-open co-driver screen
Line 197838: 05-18 11:28:28.539 5520 6687 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-open co-driver screen
Line 200241: 05-18 11:28:37.545 5520 6739 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-already open co-driver screen
Line 202202: 05-18 11:28:46.546 5520 6631 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-already open co-driver screen
Line 204667: 05-18 11:28:55.542 5520 6739 I HFSEM_REMOTE_CTRL: RemoteControlOpenApiManager-already open co-driver screen
遥控器收到语音指令第一次打开副屏后 未重置请求状态 导致一直向服务端发送打开副屏 该逻辑已修改 新版本验证