Bug #117854
【BSP】【VX1】【Display】烧写0506 db后设备开机, 先出现一小段开机动画,然后就黑屏,投屏显示正常,热插拔一下屏幕连接线 恢复正常
Status: | CLOSED | Start date: | 2023-05-10 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0506 db | |
Resolution: | FIXED | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | ||
Test Type: | ST | Root cause: | VX1屏端有心跳检测机制,需要定时往屏端写寄存器 |
Description
前置条件
VX板子
操作步骤:
1.Qile烧写 0506 的db
2.设备开机,查看现象
3.重新插拔显示线
预期结果:
1.fota升级流程正常结束,设备自动重启
实际结果:
2.设备正常显示,TP正常
3.设备正常显示、TP正常
如何恢复
2.设备出现黑屏
3.设备正常显示、TP正常
History
#1 Updated by CD BSP-杜磊 about 2 years ago
- Status changed from New to ASSIGNED
- % Done changed from 0 to 50
- Root cause set to VX1屏端有心跳检测机制,需要定时往屏端写寄存器
#2 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
198996 | general/kernel/msm-4.19 | Pre_figure_turbox-c2130c-la1.1-vendor-dev | dulei0503@thundersoft.com |
BSP:Display: Fix VX1 black screen caused by heartbeat VX1 lcd need per 2s to wirte register to keep lcd alive, if exceeds about 17 seconds, the LCD will go blank. TC-RID: 1201-0100501 IssueID: TS-R-DF-117854 Change-Id: I2cec5f84bc760b4fc67143ed4cb221e6b27facbf |
#3 Updated by CD BSP-杜磊 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD BSP-杜磊 to 移动测试一组_CDTS 刘强
- % Done changed from 50 to 100
- Resolution changed from -- to FIXED
#4 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Status changed from RESOLVED to VERIFIED
0100和FlatBuild_HH_MCE_FSE.M.D.user.01.00.C103.202305150054 未复现黑屏不亮屏的情况,因此关闭次issue,有其他黑屏由其他bug跟踪
https://share.thundersoft.com/redmine/issues/117953
https://share.thundersoft.com/redmine/issues/117954
https://share.thundersoft.com/redmine/issues/117955
https://share.thundersoft.com/redmine/issues/117956
#5 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Status changed from VERIFIED to CLOSED