Bug #117865

测试 Test-IT #110867: V1.0测试功能汇总

测试 Test-IT #110895: AF-V1.0功能测试-桌面

【AF】【EVT】【桌面】概率出现(1/10),本地视频播放中,断电重启后出现开机引导

Added by 物联网测试组_CDTS 唐霞 about 2 years ago. Updated about 2 years ago.

Status:CLOSEDStart date:2023-05-10
Priority:NormalDue date:
Assignee:物联网测试组_CDTS 唐霞 % Done:

100%

Category:CD-FW
Target version:-
Need_Info:-- Found Version:FlatBuild_HH_MCE_FSE.M.R.user.01.00.0098.C103(X103)
Resolution:FIXED Degrated:No
Severity:Normal Verified Version:
Reproducibility:Rarely Fixed Version:2023-05-12
Test Type:Release Test Root cause:异常断电的情况下 Provision 引导程序没有禁用成功。

Description

【测试步骤】
本地视频播放中,断电重启
【预期结果】
重启后进入桌面显示正确
【测试结果】
重启后出现开机引导

History

#1 Updated by CD FW-廖涛 about 2 years ago

  • Status changed from New to ASSIGNED
  • Assignee changed from CD FW 曹覃刚 to CD FW-廖涛
  • Priority changed from High to Normal

■ Current conclusion
由于通过中控正常激活,不会出现断电后再次进入激活引导页面的问题,且该问题为低概率问题,所以申请降低问题优先级。

High -> Normal

#2 Updated by CD FW-廖涛 about 2 years ago

  • Severity changed from Major to Normal

#3 Updated by IoT scm about 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
199516 general/platform/vendor/thundercomm/apps/TCSetupWizard Pre_figure_turbox-c2130c-la1.1-qssi12-dev
AF:FactoryMode: Fix abnormal launch activation page problem.
TC-RID: 1201-0207601
IssueID: TS-R-BUG-117865
Change-Id: Ie6a842cba24a2cefcfffd2da48c47f956379af8e

#4 Updated by IoT scm about 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
199517 general/platform/frameworks/base Pre_figure_turbox-c2130c-la1.1-qssi12-dev
AF:FactoryMode: Fix abnormal launch activation page problem.
TC-RID: 1201-0207601
IssueID: TS-R-BUG-117865
Change-Id: I65c0ab45f94db187117bededa0236d5b390304b6

#5 Updated by CD FW-廖涛 about 2 years ago

  • Status changed from ASSIGNED to RESOLVED
  • Assignee changed from CD FW-廖涛 to 物联网测试组_CDTS 唐霞
  • % Done changed from 0 to 100
  • Resolution changed from -- to FIXED
  • Degrated changed from -- to No
  • Fixed Version set to 2023-05-12
  • Root cause set to 异常断电的情况下 Provision 引导程序没有禁用成功。

■ Current conclusion
已处理,代码已入库。

■ My analysis
异常断电的情况下 Provision 引导程序没有禁用成功。

已跟进跳过激活的属性状态来关闭激活引导页面。

■ Next action
测试验证。

#6 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago

  • Status changed from RESOLVED to VERIFIED

验证通过,关闭问题单
验证版本:FlatBuild_HH_MCE_FSE.M.D.user.01.00.C103.202305150054

#7 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago

  • Status changed from VERIFIED to CLOSED

Also available in: Atom PDF