Bug #117865
测试 Test-IT #110867: V1.0测试功能汇总
测试 Test-IT #110895: AF-V1.0功能测试-桌面
【AF】【EVT】【桌面】概率出现(1/10),本地视频播放中,断电重启后出现开机引导
Status: | CLOSED | Start date: | 2023-05-10 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 物联网测试组_CDTS 唐霞 | % Done: | 100% | |
Category: | CD-FW | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | FlatBuild_HH_MCE_FSE.M.R.user.01.00.0098.C103(X103) | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Rarely | Fixed Version: | 2023-05-12 | |
Test Type: | Release Test | Root cause: | 异常断电的情况下 Provision 引导程序没有禁用成功。 |
Description
【测试步骤】
本地视频播放中,断电重启
【预期结果】
重启后进入桌面显示正确
【测试结果】
重启后出现开机引导
History
#1 Updated by CD FW-廖涛 about 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD FW 曹覃刚 to CD FW-廖涛
- Priority changed from High to Normal
■ Current conclusion
由于通过中控正常激活,不会出现断电后再次进入激活引导页面的问题,且该问题为低概率问题,所以申请降低问题优先级。
High -> Normal
#2 Updated by CD FW-廖涛 about 2 years ago
- Severity changed from Major to Normal
#3 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
199516 | general/platform/vendor/thundercomm/apps/TCSetupWizard | Pre_figure_turbox-c2130c-la1.1-qssi12-dev | tao.liao@thundersoft.com |
AF:FactoryMode: Fix abnormal launch activation page problem. TC-RID: 1201-0207601 IssueID: TS-R-BUG-117865 Change-Id: Ie6a842cba24a2cefcfffd2da48c47f956379af8e |
#4 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
199517 | general/platform/frameworks/base | Pre_figure_turbox-c2130c-la1.1-qssi12-dev | tao.liao@thundersoft.com |
AF:FactoryMode: Fix abnormal launch activation page problem. TC-RID: 1201-0207601 IssueID: TS-R-BUG-117865 Change-Id: I65c0ab45f94db187117bededa0236d5b390304b6 |
#5 Updated by CD FW-廖涛 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD FW-廖涛 to 物联网测试组_CDTS 唐霞
- % Done changed from 0 to 100
- Resolution changed from -- to FIXED
- Degrated changed from -- to No
- Fixed Version set to 2023-05-12
- Root cause set to 异常断电的情况下 Provision 引导程序没有禁用成功。
■ Current conclusion
已处理,代码已入库。
■ My analysis
异常断电的情况下 Provision 引导程序没有禁用成功。
已跟进跳过激活的属性状态来关闭激活引导页面。
■ Next action
测试验证。
#6 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from RESOLVED to VERIFIED
验证通过,关闭问题单
验证版本:FlatBuild_HH_MCE_FSE.M.D.user.01.00.C103.202305150054
#7 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from VERIFIED to CLOSED