Bug #117942

【IOVDEV-25481】【BSP】【EVT3】【息屏】非应用界面进入息屏,唤醒后进入应用中

Added by 物联网测试组_CDTS 唐霞 about 2 years ago. Updated about 2 years ago.

Status:CLOSEDStart date:2023-05-15
Priority:NormalDue date:
Assignee:移动测试一组_CDTS 刘强% Done:

100%

Category:BSP
Target version:-
Need_Info:-- Found Version:FlatBuild_HH_MCE_FSE.M.D.user.01.00.C103(X103).202305150054
Resolution:-- Degrated:--
Severity:Normal Verified Version:FlatBuild_HH_MCE_FSE.M.R.user.01.00.0101.C103(X103)
Reproducibility:Every time Fixed Version:
Test Type:Release Test Root cause:使用TP模式powerkey,在唤醒屏幕时,TP会持续报点,导致误触点击app

Description

【测试步骤】
在桌面首页进入控制中心点击息屏,息屏状态下点击屏幕
【预期结果】
唤醒进入桌面
【测试结果】
进入了点击屏幕出的应用中


Related issues

Related to Figure - Bug #117763: 【IOVDEV-25481】【VC1】【0072】【台架】【EE环境】【副屏】非应用界面熄屏情况下点击屏幕进入了应用 CLOSED 2023-05-05

History

#1 Updated by CD FW 曹覃刚 about 2 years ago

  • Category changed from CD-FW to BSP
  • Status changed from New to ASSIGNED
  • Assignee changed from CD APP-王营 to CD BSP-杜磊

Hi 杜磊
这个问题与 #117763 问题一致
请帮助解析

#2 Updated by CD BSP-杜磊 about 2 years ago

  • Status changed from ASSIGNED to RESOLVED
  • Assignee changed from CD BSP-杜磊 to 移动测试一组_CDTS 刘强
  • % Done changed from 0 to 100
  • Root cause set to 使用TP模式powerkey,在唤醒屏幕时,TP会持续报点,导致误触点击app

修改已入库
https://dev.thundercomm.com/gerrit/c/general/kernel/msm-4.19/+/199224

请使用DB版本验证后,close此问题

#3 Updated by 物联网测试组_TSCD 王维 about 2 years ago

  • Status changed from RESOLVED to VERIFIED
  • Verified Version set to FlatBuild_HH_MCE_FSE.M.R.user.01.00.0101.C103(X103)

#4 Updated by 物联网测试组_TSCD 王维 about 2 years ago

  • Status changed from VERIFIED to CLOSED

Also available in: Atom PDF