Bug #118086
IOVDEV-29021【VC1】【内部】【0095】【实车320】【EE环境】【副屏】【第三方应用】将副屏亮度设置最高,中控开启续航增加,副屏亮度无变化
Status: | CLOSED | Start date: | 2023-05-18 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 物联网测试组_CDTS 唐霞 | % Done: | 0% | |
Category: | 依赖客户及其供应商解决 | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 01.00.0095.C103 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
【台架号】:LJD8BC3F6P0000320
【环境信息】:EE环境
【测试时间】:2023.5.17
【前提条件】:
1、网络正常
2、副屏上电
【操作步骤】
1、副屏将亮度设置最亮
2、中控开启续航增加
【实际结果】
2、副屏亮度未降低
【期待结果】
2、开启续航增加,副屏亮度降低
【备注】:
IDCM:03.02.0080.C101/副屏:01.00.0095.C103
台架vin号:LJD8BC3F6P0000320
视频:https://ofs.human-horizons.com/#/download/index/5v7mSRrtVZE%3D
日志: tlog_iov0201017500006162025411a2212290000002821_000092_0517170805.tar.gz
History
#1 Updated by CD APP-王营 about 2 years ago
- Category changed from CD-APP to CD-FW
- Assignee changed from CD APP-王营 to CD FW-程天颖
请确认一下是否有此需求
#2 Updated by CD FW-程天颖 about 2 years ago
- Category changed from CD-FW to 依赖客户及其供应商解决
- Status changed from New to ASSIGNED
- Assignee changed from CD FW-程天颖 to 物联网测试组_CDTS 唐霞
根据需求,中控自行使用息屏接口关闭副屏屏幕即可,副屏现象应该为关闭屏幕,而不是亮度变暗
副屏息屏接口已提供,需要中控修改
#3 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
非问题,客户测试需求不明确,关闭问题单
#4 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#5 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from VERIFIED to CLOSED