Bug #118090

【IOVDEV-29252】【IOVDEV-29256】【内部】【VC1】【0095】【台架】【EE环境】【副屏】副屏通知中心显示隐藏通知的应用图标异常

Added by CD TEST-方永红 about 2 years ago. Updated about 2 years ago.

Status:CLOSEDStart date:2023-05-18
Priority:NormalDue date:
Assignee:CD TEST-方永红% Done:

100%

Category:CD-FW
Target version:-
Need_Info:-- Found Version:0095
Resolution:FIXED Degrated:No
Severity:Normal Verified Version:0106(6.1版)
Reproducibility:Occasionally Fixed Version:2023-05-31
Test Type:ST Root cause:时序问题,导致隐藏通知块设置不成功

Description

【环境信息】EE环境
【问题出现时间】:20230518 17:00
【前提条件】:车机上电(副屏已安装应用宝,QQ音乐等应用)
1.副屏中安装的第三方应用总共收到8条应用通知

2.副屏查看通知中心

【实际结果】

通知中心显示隐藏通知区域的应用图标异常

【期望结果】
通知中心显示隐藏通知区域的应用图标正常

【车架号】:

【备注】:

log地址:https://ofs.human-horizons.com/#/download/index/Cn34jwuHzC4%3D

【影响版本】:副屏:01.00.0095.c103

14点11分复现通知中心显示图标异常问题.mp4 (13.4 MB) CDTS_TEST 王成, 2023-05-27 19:45

History

#1 Updated by CD TEST-方永红 about 2 years ago

  • Subject changed from 【IOVDEV-29252】【内部】【VC1】【0095】【台架】【EE环境】【副屏】副屏通知中心显示隐藏通知的应用图标异常 to 【IOVDEV-29252】【IOVDEV-29256】【内部】【VC1】【0095】【台架】【EE环境】【副屏】副屏通知中心显示隐藏通知的应用图标异常

#2 Updated by CD FW 曹覃刚 about 2 years ago

  • Category changed from CD-FW to 依赖客户及其供应商解决
  • Status changed from New to NEED_INFO
  • Assignee changed from CD FW 曹覃刚 to CD TEST-方永红

■ 当前状态
UI类问题,日志作用小

■ 下一步计划
1.需要测试同学先帮忙找出问题的复现方式
2.在研发侧复现问题并调试UI,研发解析及修复和验证的前提都要将问题复现出来

目前按照票上的问题没有办法复现这个问题,需要找到确切的复现步骤
请帮忙联系客户侧测试找下复现问题的步骤

#3 Updated by CDTS_Test 吴诗雨 about 2 years ago

已同步

#4 Updated by CDTS_TEST 王成 about 2 years ago

5月27日14点10分副屏重启,14点11分发进行测试复现此问题操作:

1.向下滑动查看通知中心,显示隐藏通知正常

2.设置-显示中字体大小最大,查看通知中心

现象:通知中心中隐藏通知图标显示异常
新LOG:ftp://cdiot@192.168.87.46/Pre_figure/Test_Log/118090/tlog_iov0201017500006162025411a2212290000000911_000209_0527141403.tar.gz

#5 Updated by CD FW 曹覃刚 about 2 years ago

  • Category changed from 依赖客户及其供应商解决 to CD-FW

■ 我的分析
能够通过测试步骤,复现出部分问题现象

■ 下一步计划
调试修复问题

#6 Updated by IoT scm about 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
203544 general/platform/frameworks/base Pre_figure_turbox-c2130c-la1.1-qssi12-dev
AF:Notification: Fix the problem of unsuccessful visibility update due to timing problem
TC-RID: 1201-0201902
IssueID: TS-R-BUG-118090
Change-Id: I18df45c87183533493f96186f02123aed42cd991

#7 Updated by CD FW 曹覃刚 about 2 years ago

  • Status changed from ASSIGNED to RESOLVED
  • Assignee changed from CD FW 曹覃刚 to CD TEST-方永红
  • % Done changed from 0 to 100
  • Resolution changed from -- to FIXED
  • Degrated changed from -- to No
  • Fixed Version set to 2023-05-31
  • Root cause set to 时序问题,导致隐藏通知块设置不成功

#8 Updated by CD TEST-方永红 about 2 years ago

  • Status changed from RESOLVED to VERIFIED
  • Verified Version set to 0106(6.1版)

根据步骤不复现此问题

#9 Updated by CD TEST-方永红 about 2 years ago

  • Status changed from VERIFIED to CLOSED

Also available in: Atom PDF