Bug #118828
【AF】【桌面】低概率出现,频繁点击仅息副驾屏后,应该亮屏,但屏幕没有亮的情况
Status: | CLOSED | Start date: | 2023-06-17 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 物联网测试组_CDTS 唐霞 | % Done: | 100% | |
Category: | CD-FW | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 110(6/16)合入荔枝播客版本 | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | 2023-06-26 | |
Test Type: | Release Test | Root cause: | 微服务消息发送时序问题 |
Description
前置条件:
1.设备连接中控,网络正常
2.在中控执行
adb root
adb shell
ssh root@223.255.255.1
dbus-send --bus=tcp:host=223.255.255.1,port=55666 --type=signal / ipcl.out.to.droid.SWC2VHAL_COMM array:byte:3,51,1
【测试步骤】
中控进入设置-显示-息屏模式,频繁点击“仅副驾屏”
【预期结果】
屏幕状态显示正确
【测试结果】
副屏应该亮屏,但屏幕没有亮是息屏状态
History
#1 Updated by CD FW 曹覃刚 about 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD FW 曹覃刚 to CD FW-廖涛
#2 Updated by CD FW-廖涛 about 2 years ago
■ Current conclusion
1. 微服务消息发送时序问题;
2. 中控息屏“仅副驾屏”高亮状态问题;
问题 1 已经处理,问题 2 需要中控确认,已联系;
■ Next action
联系中控开发确认高亮状态;
#3 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
209490 | general/platform/vendor/thundercomm/apps/MircoService | Pre_figure_turbox-c2130c-la1.1-qssi12-dev | tao.liao@thundersoft.com |
AF:MicroService: Fixed send message timing confusion. TC-RID: 1201-0206101 IssueID: TS-R-BUG-118828 Change-Id: If7fe09795736e6d5eb89b6dc5aff1960d78ab2e6 |
#4 Updated by CD FW-廖涛 about 2 years ago
- Status changed from ASSIGNED to RESOLVED
- Assignee changed from CD FW-廖涛 to 物联网测试组_CDTS 唐霞
- % Done changed from 0 to 100
- Resolution changed from -- to FIXED
- Degrated changed from -- to No
- Fixed Version set to 2023-06-26
- Root cause set to 微服务消息发送时序问题
■ Current conclusion
已处理,代码已入库。
■ My analysis
微服务消息发送时序问题,微服务消息发送已处理为同一 DestService 按照顺序发送。
■ Next action
测试验证。
#5 Updated by IoT scm about 2 years ago
Gerrit Merge Information:
ID | Project | Branch | Uploader |
209948 | general/platform/vendor/thundercomm/apps/MircoService | Pre_figure_turbox-c2130c-la1.1-qssi12-release_sorp | wangxl0510@thundersoft.com |
AF:MicroService: Fixed send message timing confusion. TC-RID: 1201-0206101 IssueID: TS-R-BUG-118828 Change-Id: If7fe09795736e6d5eb89b6dc5aff1960d78ab2e6 (cherry picked from commit e56874bdde668372712cd6542460fdaab1e37774) |
#6 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
验证100次未复现
验证版本114release(627)
#7 Updated by 物联网测试组_CDTS 唐霞 almost 2 years ago
- Status changed from RESOLVED to VERIFIED
验证通过关闭问题单
验证版本:release119(704)
#8 Updated by 物联网测试组_CDTS 唐霞 almost 2 years ago
- Status changed from VERIFIED to CLOSED