Bug #118954
【AF】【系统】【TP】概率出现,断电重启后TP不可用
Status: | CLOSED | Start date: | 2023-07-01 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | 物联网测试组_CDTS 唐霞 | % Done: | 0% | |
Category: | 冻屏 | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 116版本 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Frequently | Fixed Version: | ||
Test Type: | Release Test | Root cause: | 屏端更新了新固件导致的 |
Description
【问题描述】
概率出现,断电重启后TP不可用
History
#1 Updated by CD TPM-王祥林 about 2 years ago
- Status changed from New to RESOLVED
- Assignee changed from CD TPM-王祥林 to 物联网测试组_CDTS 唐霞
- Found Version changed from 116热了版本 to 116版本
- Root cause set to 屏端更新了新固件导致的
已回退屏端固件解决此问题,在117版本验证。
https://dev.thundercomm.com/gerrit/c/general/vendor/thundercomm/products/figure/+/211902
#2 Updated by 物联网测试组_CDTS 唐霞 almost 2 years ago
117版本验证50次未复现。屏端问题关闭问题单
#3 Updated by 物联网测试组_CDTS 唐霞 almost 2 years ago
- Status changed from RESOLVED to VERIFIED
#4 Updated by 物联网测试组_CDTS 唐霞 almost 2 years ago
- Status changed from VERIFIED to CLOSED