Bug #119017

【AF】【EVT3】设备上电后6 7秒插入屏幕投屏线,设备冻屏,断电重启恢复

Added by CD TEST-方永红 almost 2 years ago. Updated almost 2 years ago.

Status:CLOSEDStart date:2023-07-10
Priority:HighDue date:
Assignee:CD TEST-方永红% Done:

100%

Category:BSP
Target version:-
Need_Info:-- Found Version:01.00.0120.C106(X106)
Resolution:-- Degrated:--
Severity:Critical Verified Version:
Reproducibility:Every time Fixed Version:
Test Type:ST Root cause:

Description

【测试版本】
01.00.0120.C106

【测试步骤】
设备上电后6 7秒插入屏幕投屏线,设备冻屏,断电重启恢复

History

#1 Updated by CD BSP-余霄 almost 2 years ago

  • Status changed from New to RESOLVED
  • Assignee changed from CD BSP-余霄 to CD TEST-方永红
  • % Done changed from 0 to 100

修改链接:
https://dev.thundercomm.com/gerrit/c/general/kernel/msm-4.19/+/213974

验证版本:
/Figure/VerifyBuild/Pre_figure_turbox-c2130c-la1.1-qssi12-dev/20230711/202307112158-1229

自验证:
上电UEFI流程跑完插入GMSL,显示OK、touch OK
上电atmel驱动跑完插入GMSL,显示OK、touch OK
上电到进入系统桌面插入GMSL,显示OK、touch OK
热插拔验证,显示OK、touch OK

#2 Updated by IoT scm almost 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
213974 general/kernel/msm-4.19 Pre_figure_turbox-c2130c-la1.1-vendor-dev
BSP:TP: Fix ATMEL cold plug and hot plug problems
Fix ATMEL cold plug and hot plug problems
TC-RID: 1201-0100401
IssueID: TS-R-DF-119017
Change-Id: Ib85a9b1105c846cfef204228194a47010b930054

#3 Updated by IoT scm almost 2 years ago

Gerrit Merge Information
ID Project Branch Uploader
214145 general/kernel/msm-4.19 Pre_figure_turbox-c2130c-la1.1-vendor-release_sorp
BSP:TP: Fix ATMEL cold plug and hot plug problems
Fix ATMEL cold plug and hot plug problems
TC-RID: 1201-0100401
IssueID: TS-R-DF-119017
Change-Id: Ib85a9b1105c846cfef204228194a47010b930054
(cherry picked from commit 4d2c315d5fd9885dbdf2663a2d6bd12f1ab2a251)

#4 Updated by CD TEST-方永红 almost 2 years ago

  • Status changed from RESOLVED to VERIFIED

0713DB验证20次未复现
0122验证10次未复现

#5 Updated by CD TEST-方永红 almost 2 years ago

  • Status changed from VERIFIED to CLOSED