Bug #119080
【BSP】【EVT3】【TP】新屏125版本,设备熄屏后,点击屏幕亮屏界面会闪烁一次后亮屏
Status: | ASSIGNED | Start date: | 2023-07-21 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | CD BSP-余霄 | % Done: | 0% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 125 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | ST | Root cause: |
Description
【前提条件】
None
【测试步骤】
1. 使用新屏+新固件控制器
2. 点击熄屏
3. 点击屏幕亮屏
【预期结果】
3 设备可以正常亮屏
【实际结果】
3 设备界面会闪一次再亮屏
History
#1 Updated by CD TPM-王祥林 almost 2 years ago
- Assignee changed from CD TPM-王祥林 to CD FW 曹覃刚
#2 Updated by CD FW-廖涛 almost 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD FW 曹覃刚 to CD FW吴宇航
#3 Updated by CD FW吴宇航 almost 2 years ago
- Assignee changed from CD FW吴宇航 to CD BSP-余霄
使用125版本进行验证
确定问题只在新屏设备上都可以复现
旧屏都没有复现。
FW层检查了两边的日志,未找到可疑日志信息。
麻烦屏幕相关的同事继续调查一下
谢谢
#4 Updated by CD BSP-余霄 almost 2 years ago
出现的问题在新屏上,正在与供应商沟通。
#5 Updated by CD FW 曹覃刚 over 1 year ago
- Category changed from CD-FW to BSP