Bug #111446

测试 Test-IT #110867: V1.0测试功能汇总

测试 Test-IT #110868: BSP-BVT测试-上/下电测试

【BSP】【EVT】【power】【必现】直流电源同时给板子和屏幕供电,线路上连接KL15开关;mcu手动升级完成后,关闭KL15开关后,板子和屏幕未断电

Added by SZTS_TEST 邹涛 almost 3 years ago. Updated almost 3 years ago.

Status:CLOSEDStart date:2022-08-25
Priority:HighDue date:
Assignee:SZ BSP-徐季源% Done:

100%

Category:BSP
Target version:-
Need_Info:-- Found Version:0.0.0.20220824_alpha_private_userdebug
Resolution:-- Degrated:--
Severity:Critical Verified Version:
Reproducibility:Every time Fixed Version:
Test Type:Bring Up Test Root cause:

Description

前置条件:
1、DUT各模块功能正常且处于开机状态
2、直流电源同时给板子和屏幕供电,线路上连接KL15开关
3、mcu相关的bin文件已经push到指定目录

操作步骤:
1、打开mcuUpgrade应用,点击绑定UART服务,等待5s后再次点击发送请求升级指令
2、等待mcu升级完成后,关闭KL15开关
3、查看板子和屏幕是否掉电关机

实际结果:
1、mcu升级完成后,关闭KL15开关;板子和屏幕未掉电关机
2、正常开机状态下,关闭KL15开关,等待一会后板子和屏幕会掉电关机

预期结果:
1、mcu升级完成后,关闭KL15开关;等待一会后板子和屏幕会掉电关机

logcat.txt Magnifier (5.62 MB) SZTS_TEST 邹涛, 2022-08-25 17:12

History

#1 Updated by SZ BSP-徐季源 almost 3 years ago

  • Status changed from New to RESOLVED
  • % Done changed from 0 to 100

这个问题主要是因为电源控制位于 App 侧,进行升级时,MCU 跳转到 Boot 侧,无法对 KL15 进行响应。

现版本升级成功后,触发 865 关机(例如:adb reboot)可以触发 MCU 重启,进入 App 侧,之后可以正常响应电源控制。

#2 Updated by SZTS_TEST 邹涛 almost 3 years ago

0.0.0.20220830_alpha_private_userdebug,版本验证mcu升级完成后会自动重启,不会出现上述操作,故关闭该bug

#3 Updated by SZTS_TEST 邹涛 almost 3 years ago

  • Status changed from RESOLVED to VERIFIED

#4 Updated by SZTS_TEST 邹涛 almost 3 years ago

  • Status changed from VERIFIED to CLOSED

#5 Updated by CD TPM-申艳艳 almost 3 years ago

  • Category set to BSP

Also available in: Atom PDF