Bug #112119
测试 Test-IT #110867: V1.0测试功能汇总
测试 Test-IT #110868: BSP-BVT测试-上/下电测试
【VX1】【BSP】【EVT】【风扇】【必现】设备风扇始终不转
Status: | CLOSED | Start date: | 2022-09-23 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | SZTS_TEST 邹涛 | % Done: | 100% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | FlatBuild_VX1_MCE_xx.xx_FSE.R.userdebug.0.0.0.20220922.alpha_0017 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Critical | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Bring Up Test | Root cause: |
Description
前置条件
1、DUT各模块功能正常且连接风扇
操作步骤:
1、设备上电开机,查看风扇状态
2、使用风筒吹板子使板子cpu温度升高到75°以上,查看风扇状态
实际结果:
1、风扇不转
2、风扇不转
预期结果:
1、开机风扇维持在5000转
2、cpu温度升高到75°后,风扇转速提高到7000转
History
#1 Updated by CD BSP-杜磊 almost 3 years ago
- Assignee changed from CD BSP-杜磊 to SZTS_TEST 邹涛
- % Done changed from 0 to 100
请使用9/24的版本验证
#2 Updated by SZTS_TEST 邹涛 almost 3 years ago
0924release版本验证
风扇在开机时会自动转动一次,之后根随主板温度转动、测试过程中升温可以使用电吹风进行加热,并使用命令实时查看温度值
当前的风扇分为三档:一档转速比值102、二档153、三档204
温度对应的风扇动作:
1、0~49.9 风扇不动
2、50~60,风扇一档
3、60~75.风扇为二档
4、75以上、风扇为三档"
#3 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Status changed from New to RESOLVED
#4 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Status changed from RESOLVED to VERIFIED
#5 Updated by SZTS_TEST 邹涛 almost 3 years ago
- Status changed from VERIFIED to CLOSED