Bug #113247
【EVT1】【BSP】【Power】【必现】整车上下电,板子未正常启动卡在android动画界面,adb可以使用
Status: | CLOSED | Start date: | 2022-10-28 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | CDTS_TEST 刘勇 | % Done: | 100% | |
Category: | 客户工厂bug跟踪 | |||
Target version: | VX1_MCE_FSE_V3.0_update_20221115 | |||
Need_Info: | -- | Found Version: | 见附件图片-imav2__0 | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | 2022-10-31 | |
Test Type: | IT | Root cause: | 原生问题
修复方案已入库于10/21, 请使用10/21之后的版本进行测试 |
Description
【前提】
刷机烧录版本
【操作步骤】
整车上电
【实际结果】
板子未正常启动,卡在Andorind动画界面
【期望结果】
板子正常启动,动画流畅
History
#1 Updated by CDTS_TEST 刘勇 over 2 years ago
- Category changed from 客户jira bug to 客户工厂bug跟踪
#2 Updated by CD BSP-唐金泽 over 2 years ago
- Status changed from New to ASSIGNED
- Assignee changed from CD BSP-唐金泽 to CD FW 曹覃刚
从现象和dmesg上看,和之前烧录Android系统未启动就断电,导致系统无法启动一致。
AF同事也帮忙check下log呢?是否属于同根问题
#3 Updated by CDTS_TEST 王成 over 2 years ago
- Target version changed from VX1_MCE_FSE_V3.0_20221030 to VX1_MCE_FSE_V3.0_update_20221115
#4 Updated by CD FW 曹覃刚 over 2 years ago
- Status changed from ASSIGNED to RESOLVED
- % Done changed from 0 to 100
- Resolution changed from -- to FIXED
- Root cause set to 原生问题 修复方案已入库于10/21, 请使用10/21之后的版本进行测试
已修复,提交如下
入库于10/21, 请使用10/21之后的版本进行测试
https://dev.thundercomm.com/gerrit/c/general/platform/frameworks/base/+/157078
#5 Updated by CD FW 曹覃刚 over 2 years ago
- Degrated changed from -- to No
- Fixed Version set to 2022-10-31
#6 Updated by CD BSP-唐金泽 over 2 years ago
- Assignee changed from CD FW 曹覃刚 to CDTS_TEST 刘勇
#7 Updated by CDTS_TEST 刘勇 over 2 years ago
【HW】EVT2-VC1
【SW】FlatBuild_HH_VX1_MCE_FSE.M.D.user.01.00.X101.202211050252
【前提】
刷机烧录版本
【操作步骤】
整车上电
【实际结果】
板子正常启动,高合动画流畅。无Andorid动画
【测试次数】5次
【验证结果】PASS,验证通过
#8 Updated by CDTS_TEST 刘勇 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#9 Updated by CDTS_TEST 刘勇 over 2 years ago