Bug #114492
【Figure】【EVT2】【EMC】CE02 电磁传导发射:CE电压法 32MHz 附近PK超限值12.78dB,AV超限值11.33dB;CE电流法 32MHz附近PK超20.46dB,AV超19dB
Status: | CLOSED | Start date: | 2022-12-12 | |
---|---|---|---|---|
Priority: | High | Due date: | 2023-01-20 | |
Assignee: | SZ HW Test-曾小文 | % Done: | 0% | |
Category: | EE | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | FlatBuild_HH_VX1_MCE_FSE.M.D.userdebug.01.00.X101.202211212354 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | Release Test | Root cause: |
Description
CE02 电磁传导发射:CE电压法 32MHz 附近PK超限值12.78dB,AV超限值11.33dB;CE电流法 32MHz附近PK超20.46dB,AV超19dB
History
#1 Updated by SZ HW Test-曾小文 over 2 years ago
- Priority changed from Normal to High
#2 Updated by SZ HW Test-曾小文 over 2 years ago
- Category set to EE
#3 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- Due date set to 2023-01-20
- Status changed from New to NEED_INFO
苏州SGS实验室之前测试底噪不通过,以上数据没有参考性。实验室给出时间是本周1月20日复测完成。
#4 Updated by SZ-硬件二组_SD3 王苗 over 2 years ago
- File FSE EMC CE电流法复测试分析报告-0211.pptx added
- Status changed from NEED_INFO to RESOLVED
- Assignee changed from SZ-硬件二组_SD3 王苗 to SZ HW Test-曾小文
已经复测整改测试环境,复测结果整理报告,发给客户,客户EMC工程师同意接受测试结果。
#5 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#6 Updated by SZ HW Test-曾小文 over 2 years ago
- Status changed from VERIFIED to CLOSED