Bug #114664
【BSP】【EVT2】【FOTA】升级后,回滚失败
Status: | CLOSED | Start date: | 2022-12-16 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | CDTS_TEST 刘勇 | % Done: | 0% | |
Category: | BSP | |||
Target version: | VX1_MCE_FSE_V5.0_20221230 | |||
Need_Info: | -- | Found Version: | FlatBuild_HH_VX1_MCE_FSE.M.D.user.01.00.X101.202212140521 | |
Resolution: | -- | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | IT | Root cause: |
Description
【前提条件】
1.中控环境搭建好
2.中控环境中有全量包
【测试步骤】
3.中控通过网线链接路由,路由通过网线或者wifi 链接DUT
4.中控IP:192.168.0.2 ,DUT-IP:192.168.0.18
5.进入终端,cd ~/server/目录,并运行命令
sudo ./run_https.sh
sudo ./run_orch.sh
adb shell logcat > logcat-screnen-not_black.txt
6.待功能启动
7.选择功能2(Download PACKAGE)
输入"2"->按"回车" ->输入 "1"->输入"update.zip"
8.等待下载完成并选择运行功能0(run script )
输入 "0"-> 按"回车"->等待log中有提示下载完成(download succesful)->“adb reboot "
9.等待升级完成后,运行功能1(Rollback)
输入 “1 ” ->按“回车”-->等待提示"rollback done 100% ,done" ->"adb reboot"
【期望结果】
9.回滚成功
【实际结果】
4.回滚失败
Related issues
History
#1 Updated by CD BSP 叶鹏 over 2 years ago
- Status changed from New to NEED_INFO
- Assignee changed from CD BSP 叶鹏 to BPD-TMBG 刘勇
操作方式存在错误:
升级成功在重启之前是不会切换slot的,需要升级成功且重启设备之后,才能执行回滚的操作:
在升级之前检查slot;
在升级成功且重启设备之后,需要查看切换之后的slot
然后执行回滚命令之后,需要重启设备,设备重启之后再次检查回滚之后的slot
#2 Updated by CDTS-TEST 周婷 over 2 years ago
- Assignee changed from BPD-TMBG 刘勇 to CDTS_TEST 刘勇
#3 Updated by CDTS_TEST 刘勇 over 2 years ago
测试人员操作失误,需要重启升级成功后回滚,关闭此单
#4 Updated by CDTS_TEST 刘勇 over 2 years ago
- Status changed from NEED_INFO to RESOLVED
#5 Updated by CDTS_TEST 刘勇 over 2 years ago
- Status changed from RESOLVED to VERIFIED
#6 Updated by CDTS_TEST 刘勇 over 2 years ago
- Status changed from VERIFIED to CLOSED