Bug #117422
【IOVISSUE-2794】【VC1】【质量】【IDCM】车辆行驶中仪表和中控正常显示副屏黑屏
Status: | CLOSED | Start date: | 2023-04-12 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 0% | |
Category: | CD-FW | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 【软件版本】:IDCM 03.02.0056.C101.02 | |
Resolution: | DUPLICATE | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | ||
Test Type: | ST | Root cause: | 同116260 |
Description
【问题描述】:【VC1】【质量】【IDCM】车辆行驶中仪表和中控正常显示副屏黑屏
【前置条件】:车辆正常行驶
【软件/网络环境】:Pro环境
【软件版本】:IDCM 03.02.0056.C101.02
【提报人】:李鑫宇
【操作步骤】:车辆正常行驶
【预期结果/行为】:仪表,副屏和中控正常显示
【实际结果/行为】:仪表和中控正常显示副屏黑屏
【问题发生频率】: 偶发
【实车VIN】: LJD8BC3F8P0000335
【发生日期 & 时间】:2023/03/10 13:45
【数采仪编号】:0300135
【视频链接】:见附件
History
#1 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
目前正与客户沟通提供相关日志
#2 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
关联客户jira编号2794
#3 Updated by CD TPM-王祥林 about 2 years ago
- Status changed from New to RESOLVED
- Assignee changed from CD TPM-王祥林 to 移动测试一组_CDTS 刘强
- Resolution changed from -- to DUPLICATE
- Root cause set to 同116260
通过车号和问题发生时间看,和116260是同一个问题,都是盐城路测发现的。已经修改KL15检测方式路测中,目前未发现黑屏现象。
#4 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
20230414:与116260同件,保留持续跟踪,需要确认客户现场日后是否复现
#6 Updated by 移动测试一组_CDTS 刘强 about 2 years ago
- Status changed from VERIFIED to CLOSED