Bug #117887
【IOVDEV-27166】【内部】【VC1】【0072】【台架】【EE环境】【副屏】KL15off情况下,副屏还能亮屏
Status: | CLOSED | Start date: | 2023-05-11 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | CDTS_Test 吴诗雨 | % Done: | 0% | |
Category: | BSP | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 副屏版本:01.00.0095.c103 | |
Resolution: | INVALID | Degrated: | -- | |
Severity: | Normal | Verified Version: | ||
Reproducibility: | Every time | Fixed Version: | ||
Test Type: | ST | Root cause: |
Description
【环境信息】EE环境
【问题出现时间】:20230510 19:53
【前提条件】:KL30 ON,副屏未亮屏
1. 中控连接KL30ON(CAN信号BACM_PowerMode为OFF,所以中控未亮屏)
【实际结果】
中控连接KL30ON,副屏KL15 OFF情况下,副屏亮屏
【期望结果】
KL15 OFF情况下,副屏不亮屏
【车架号】:
【备注】:
log地址:https://ofs.human-horizons.com/#/download/index/S9GuaeCOLI8%3D
视频地址:https://ofs.human-horizons.com/#/download/index/tp3YpNO%2F2%2FE%3D
【影响版本】:副屏:01.00.0095.c103
【硬件版本号】:/
【是否能恢复】:
History
#1 Updated by CDTS_Test 吴诗雨 about 2 years ago
#2 Updated by CD TPM-王祥林 about 2 years ago
- File 飞书20230512-111808.mp4 added
#3 Updated by CD TPM-王祥林 about 2 years ago
- Status changed from New to NEED_INFO
- Assignee changed from CD TPM-王祥林 to CDTS_Test 吴诗雨
请客户确认以下信息:
从复现视频看,在KL30 ON之后,副屏直接亮屏了没有开机动画,并且直接显示设置界面。所以KL30 ON之前副屏控制器并没有关机。
1.请确认之前是不是只把屏幕断电了,没有断副屏控制器的电。
2.请确认复现之前,副屏控制器和屏幕是通过什么方式断电的,直接断KL30还是,断KL15?还是其他方式?
#4 Updated by CD TPM-王祥林 about 2 years ago
- Status changed from NEED_INFO to RESOLVED
和客户已经沟通,他们只是断了屏幕的电,并没有断控制器的电,所以控制器并不会重新关机和重新开机,屏幕供电后马上显示属于正常行为。
#5 Updated by CD TPM-王祥林 about 2 years ago
- Resolution changed from -- to INVALID
#6 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#7 Updated by CDTS_Test 吴诗雨 about 2 years ago
- Status changed from VERIFIED to CLOSED