Description
【环境信息】EE环境
【问题出现时间】:2023.5.19 10:46
【前提条件】:
1.副屏正常开机
2.页面显示正常
【操作步骤】:
1、语音输入”关闭副屏“
2、手动点击副屏,打开副屏
【实际结果】:
副屏显示7秒后自动熄屏
【期望结果】:
打开副屏后,未触发熄屏操作,不会自动熄屏
【备注】:
第974次开机
日志链接:https://ofs.human-horizons.com/#/download/index/SjhATiKkY0Q%3D
【应用版本】:
【VIN号】:LJD8BC3F3P0000310
【中控版本号】:03.02.0080.C101.03
【副屏版本号】:01.00.0095.c103
History
#1 Updated by CDTS-TEST 周婷 about 2 years ago
- Category set to CD-FW
#2 Updated by CD FW 曹覃刚 about 2 years ago
- Category changed from CD-FW to 依赖客户及其供应商解决
- Status changed from New to NEED_INFO
- Assignee changed from CD FW 曹覃刚 to 物联网测试组_CDTS 唐霞
Hi 唐霞
------------
//收到中控指令熄灭屏幕
05-19 10:46:19.869 2281 5661 D RemoteControlService: After desEncrypt json is [{"type":"power","source":0,"token":"fKNz3ZfaRIngwKZ","value":"click"}]
05-19 10:46:19.876 1502 1502 I PowerManagerService: Powering off display group due to power_button (groupId= 0, uid= 1000)...
05-19 10:46:19.877 2281 2384 D RemoteControlService: Send message finished. direction: 16, messageType: 5, json: {"source":0,"token":"fKNz3ZfaRIngwKZ","type":"power","value":true}
//手动点亮屏幕
05-19 10:46:32.105 1502 1704 I PowerManagerService: Powering on display group fromAsleep (groupId=0, uid=1000, reason=WAKE_REASON_POWER_BUTTON, details=android.policy:POWER)...
//五秒后又收到中控指令,导致屏幕熄灭了
05-19 10:46:37.866 2281 5703 D RemoteControlService: After desEncrypt json is [{"type":"power","source":0,"token":"fKNz3ZfaRIngwKZ","value":"click"}]
05-19 10:46:37.873 1502 1502 I PowerManagerService: Powering off display group due to power_button (groupId= 0, uid= 1000)...
05-19 10:46:37.875 2281 2384 D RemoteControlService: Send message finished. direction: 16, messageType: 5, json: {"source":0,"token":"fKNz3ZfaRIngwKZ","type":"power","value":true}
------------
需要中控的同事帮忙分析下,五秒后发送power指令的原因
#3 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from NEED_INFO to RESOLVED
验证10次未复现。jira单已同步更新信息,该单已关闭
#4 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from RESOLVED to VERIFIED
#5 Updated by 物联网测试组_CDTS 唐霞 about 2 years ago
- Status changed from VERIFIED to CLOSED