Bug #118967
【AF】【DVT】【eth】【偶现】KL15 断电-上电压测后,出现中控网络图标未同步
Status: | CLOSED | Start date: | 2023-07-03 | |
---|---|---|---|---|
Priority: | High | Due date: | ||
Assignee: | 移动测试一组_CDTS 刘强 | % Done: | 100% | |
Category: | CD-FW | |||
Target version: | - | |||
Need_Info: | -- | Found Version: | 0116 | |
Resolution: | FIXED | Degrated: | No | |
Severity: | Major | Verified Version: | ||
Reproducibility: | Occasionally | Fixed Version: | 2023-07-11 | |
Test Type: | ST | Root cause: | WIFI 同步问题。 |
Description
【测试版本】
中控0092
副屏0116
【测试步骤】
1、KL15 断电-上电压测后
2、副屏重启后,查看副屏时间及网络图标显示
->中控网络满格,副屏网络0格,时间不同步
【恢复方式】
1. 重启之后网络、时间、音量、亮度均正常同步
2. 手动调节一次音量,副屏马上同步了网络信号
Related issues
History
#1 Updated by CD FW 曹覃刚 about 2 years ago
- Category changed from BSP to CD-FW
#2 Updated by CD FW-廖涛 almost 2 years ago
- Status changed from New to NEED_INFO
- Assignee changed from CD FW-廖涛 to 移动测试一组_CDTS 刘强
- Need_Info changed from -- to TEST
■ Current conclusion
从目前的日志看,每次开机后,微服务启动正常,并且在与中控建立连接后,正常同步了时间和网络信号。
目前通过其他网络同步相关问题分析,出现 WIFI 信号展示不正确的问题可能是信号同步成功,但是状态栏图标设置失败的情况。
■ Next action
该问题需要帮忙复现,然后保留现场。
如出现相同问题,需要确认的现象如下:
1. 时间是否与中控同步?
2. 是否可以上网?
3. 中控是否可以通过微服务控制副屏(音量、息屏等)?
4. WIFI 图标是否可以恢复?
#3 Updated by 移动测试一组_CDTS 刘强 almost 2 years ago
- Assignee changed from 移动测试一组_CDTS 刘强 to CD FW-廖涛
问题已经复现,现场调查后需要与中控沟通
#4 Updated by CD FW-廖涛 almost 2 years ago
■ Current conclusion
从复现日志看,快速断电然后上电,中控未给副屏同步 WIFI 信号,导致副屏 WIFI 图标展示不正确。
■ Next action
需要与中控讨论优化方案。
#5 Updated by CD FW-廖涛 almost 2 years ago
- Status changed from NEED_INFO to RESOLVED
- Assignee changed from CD FW-廖涛 to 移动测试一组_CDTS 刘强
- % Done changed from 0 to 100
- Need_Info changed from TEST to --
- Resolution changed from -- to FIXED
- Degrated changed from -- to No
- Fixed Version set to 2023-07-11
- Root cause set to WIFI 同步问题。
■ Current conclusion
已处理,代码已入库。提交:https://dev.thundercomm.com/gerrit/c/general/platform/vendor/thundercomm/apps/VehicleControl/+/214033
■ My analysis
处理方式:微服务与中控处于连接状态,微设定绑定微服务成功后,主动请求中控获取 Wifi 与热点信息。
■ Next action
测试验证。
#6 Updated by 移动测试一组_CDTS 刘强 almost 2 years ago
- Status changed from RESOLVED to VERIFIED
DB_0712:压测断电-重启、adb reboot\OTA升级合计20次未复现
DB_0713:压测断电-重启、adb reboot\OTA升级合计20次未复现
#7 Updated by 移动测试一组_CDTS 刘强 almost 2 years ago
- Status changed from VERIFIED to CLOSED