Bug #114665

【BSP】【EVT2】【FOTA】增量包升级失败

Added by CDTS_TEST 刘勇 over 2 years ago. Updated over 2 years ago.

Status:CLOSEDStart date:2022-12-16
Priority:HighDue date:
Assignee:移动测试一组_CDTS 刘强% Done:

0%

Category:BSP
Target version:VX1_MCE_FSE_V5.0_20221230
Need_Info:-- Found Version:FlatBuild_HH_VX1_MCE_FSE.M.D.user.01.00.X101.202212140521
Resolution:WONTFIX Degrated:No
Severity:Normal Verified Version:
Reproducibility:Every time Fixed Version:
Test Type:IT Root cause:需求变更,暂不处理

Description

【前提条件】
1.中控环境搭建好
2.中控环境中有全量包(FTP中文件名为:merged-qssi_figure-ota.zip )

【测试步骤】
2.用"增量包"(incr_ota-figure-user.zip)替换掉"全量包"并将其改为"update.zip"
3.中控通过网线链接路由,路由通过网线或者wifi 链接DUT
4.中控IP:192.168.0.2 ,DUT-IP:192.168.0.18
5.进入终端,cd ~/server/目录,并运行命令
sudo ./run_https.sh
sudo ./run_orch.sh
adb shell logcat > logcat-screnen-not_black.txt
6.待功能启动
7.选择功能2(Download PACKAGE)
输入"2"->按"回车" ->输入 "1"->输入"update.zip"
8.等待下载完成并选择运行功能0(run script )
输入 "0"-> 按"回车"->等待log中有提示下载完成(download succesful)->“adb reboot "
9.查看能否升级

【期望结果】
9.升级成功

【实际结果】
4.升级失败

【复现概率】3/3

logcat-boxes-fota-dut_screen_not_poweroff.txt Magnifier (3.38 MB) CDTS_TEST 刘勇, 2022-12-16 22:31

logcat-boxes-fota-dut_inor_upgrade_fail.txt Magnifier (2.28 MB) CDTS_TEST 刘勇, 2022-12-16 22:45


Related issues

Copied from Figure - Bug #114663: 【BSP】【EVT2】【FOTA】副屏接收包时,不会息屏接收 CLOSED 2022-12-16
Copied to Figure - Bug #114666: 【AF】【EVT2】【FOTA】【WIFI】FOTA升级后,搜索到路由器类型从Wifi4变更为 WIFI5 CLOSED 2022-12-16
Copied to Figure - Bug #114667: 【BSP】【EVT2】【FOTA】FOTA升级后,副屏没有提示升级结果 CLOSED 2022-12-16
Copied to Figure - Bug #114668: 【BSP】【EVT2】【FOTA】全量包升级过程中 中控重启,板端后续不能重新升级 CLOSED 2022-12-16

History

#1 Updated by CD BSP 叶鹏 over 2 years ago

  • Status changed from New to NEED_INFO
  • Assignee changed from CD BSP 叶鹏 to BPD-TMBG 刘勇

使用升级包错误,应该将差分升级包解压出update.zip这个用于升级的升级包再测试

#2 Updated by CDTS-TEST 周婷 over 2 years ago

  • Assignee changed from BPD-TMBG 刘勇 to CDTS_TEST 刘勇

#3 Updated by CDTS_TEST 刘勇 over 2 years ago

  • Assignee changed from CDTS_TEST 刘勇 to CD BSP 叶鹏

使用相同版本和增量包升级,升级成功,在另外一台电脑中升级失败,出现在下载出错,麻烦研发排查一下原因。

#4 Updated by CDTS-TEST 周婷 over 2 years ago

  • Status changed from NEED_INFO to ASSIGNED

#5 Updated by CD BSP 叶鹏 over 2 years ago

  • Status changed from ASSIGNED to NEED_INFO
  • Assignee changed from CD BSP 叶鹏 to CDTS_TEST 刘勇

根据刘勇发的日志的错误信息来看是下载出错的,但是这个下载接口是博世框架提供的,我们并没有修改该部分,需要向博世提bug或者和客户沟通看如何解决

#6 Updated by CDTS_TEST 刘勇 over 2 years ago

  • Assignee changed from CDTS_TEST 刘勇 to CDTS_TEST 王成

20221229提供信息:博世FOTA不用交付了,bug、test、优化全部暂定哈

麻烦确认下此票是否关闭,如果关闭麻烦走下状态,当前状态Need_INFO,无法走到close状态

#7 Updated by CDTS-TEST 周婷 over 2 years ago

  • Status changed from NEED_INFO to RESOLVED
  • Assignee changed from CDTS_TEST 王成 to CDTS-TEST 周婷
  • Resolution changed from -- to WONTFIX
  • Degrated changed from -- to No
  • Root cause set to 需求变更,暂不处理

需求变更,博世fota 接口取消

#8 Updated by CDTS_TEST 王成 over 2 years ago

  • Assignee changed from CDTS-TEST 周婷 to 移动测试一组_CDTS 刘强

#9 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

  • Status changed from RESOLVED to VERIFIED

需求变更,关闭次issue

#10 Updated by 移动测试一组_CDTS 刘强 over 2 years ago

  • Status changed from VERIFIED to CLOSED

Also available in: Atom PDF